Preview only show first 10 pages with watermark. For full document please download

Bs En 12735-1-2001

Descripción: BS EN Code

   EMBED


Share

Transcript

Licensed Copy: Institute Of Technology Tallaght, Institute of Technology, Sun Nov 05 00:55:10 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BRITISH STANDARD BS EN 12735-1:2001 Incorporating Amendment No. 1 Copper and copper alloys — Seamless, round copper tubes for air-conditioning and refrigeration — c . w x f z b . Part 1: Tubes for piping systems w w w m o The European Standard EN 12735-1:2001, with the incorporation of amendment A1:2005, has the status of a British Standard ICS 77.150.30; 91.140.30 12&23<,1*:,7+287%6,3(50,66,21(;&(37$63(50,77('%<&23<5,*+7/$: Licensed Copy: Institute Of Technology Tallaght, Institute of Technology, Sun Nov 05 00:55:10 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BS EN 12735-1:2001 National foreword This British Standard was published by BSI. It is the UK implementation of EN 12735-1:2001, incorporating amendment A1:2005. The start and finish of text introduced or altered by amendment is indicated in the text by tags !". Tags indicating changes to CEN text carry the number of the CEN amendment. For example, text altered by CEN amendment A1:200X is indicated by !". m o The UK participation in its preparation was entrusted by Technical Committee NFE/34, Copper and copper alloys, to Subcommittee NFE/34/1, Wrought and unwrought copper and copper alloys. A list of organizations represented on NFE/34/1 can be obtained on request to its secretary. c . w x f z b . This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. Compliance with a British Standard cannot confer immunity from legal obligations. w w w This British Standard was published under the authority of the Standards Committee and comes into effect on 15 June 2001 © BSI 2006 ISBN 0 580 37091 7 Amendments issued since publication Amd. No. Date Comments 16627 29 September 2006 See national foreword Licensed Copy: Institute Of Technology Tallaght, Institute of Technology, Sun Nov 05 00:55:10 GMT+00:00 2006, Uncontrolled Copy, (c) BSI EN 12735-1 EUROPEAN STANDARD April 2001 NORME EUROPÉENNE + A1 EUROPÄISCHE NORM April 2005 ICS 23.040.15 m o English version Copper and copper alloys — Seamless, round copper tubes for air-conditioning and refrigeration — Part 1: Tubes for piping systems c . w x f z b . Cuivre et alliages de cuivre — Tubes ronds sans soudure en cuivre pour l'air conditionné et la réfrigération — Partie 1: Tubes pour canalisations Kupfer und Kupferlegierungen — Nahtlose Rundrohre aus Kupfer für die Kälte- und Klimatechnik — Teil 1: Rohre für Leitungssysteme This European Standard was approved by CEN on 6 March 2001. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Management Centre or to any CEN member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the Management Centre has the same status as the official versions. CEN members are the national standards bodies of Austria, Belgium, Czech Republic, Denmark, Finland, France, Germany, Greece, Iceland, Ireland, Italy, Luxembourg, Netherlands, Norway, Portugal, Spain, Sweden, Switzerland and United Kingdom. w w w EUROPEAN COMMITTEE FOR STANDARDIZATION COMITÉ EUROPÉEN DE NORMALISATION EUROPÄISCHES KOMITEE FÜR NORMUNG Management Centre: rue de Stassart, 36 © 2001 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. B-1050 Brussels Ref. No. EN 12735-1:2001 E Licensed Copy: Institute Of Technology Tallaght, Institute of Technology, Sun Nov 05 00:55:10 GMT+00:00 2006, Uncontrolled Copy, (c) BSI Page 2 EN 12735-1:2001 Contents Page Foreword ........................................................... 3 Introduction ...................................................... 4 1 Scope ......................................................... 4 2 Normative references ............................... 4 3 Terms and definitions .............................. 4 4 4.1 4.2 4.3 Designations ............................................. Material ....................................................... Temper ....................................................... Product ....................................................... 5 Ordering information ............................... 6 6 6.1 6.2 6.3 6.4 6.5 6.6 Requirements ........................................... Composition ................................................ Mechanical properties ................................ Dimensions and tolerances ........................ Drift expanding ........................................... Surface quality ............................................ Freedom from defects ................................ 7 Sampling ................................................... 10 5 5 5 5 Page 8 8.1 8.2 8.3 8.4 8.5 8.6 8.7 Test methods ......................................... Analysis ................................................... Tensile test .............................................. Hardness test ........................................... Drift expanding test .................................. Residue test............................................... Eddy current test ...................................... Retests ..................................................... 10 10 10 10 11 11 11 11 9 Declaration of conformity and inspection documentation .................... 12 Declaration of conformity ......................... 12 Inspection documentation ........................ 12 m o c . w x f z b . 9.1 9.2 10 6 6 7 7 10 10 10 Packaging, marking and form of delivery ................................................... 12 10.1 Packaging and marking ........................... 12 10.2 Form of delivery ....................................... 12 Annex ZA (informative) Relationship between this European Standard and the Essential Requirements of EU Directive 97/23/EC………...13 Bibliography ...................................................... 14 w w w © BSI 2006 Licensed Copy: Institute Of Technology Tallaght, Institute of Technology, Sun Nov 05 00:55:10 GMT+00:00 2006, Uncontrolled Copy, (c) BSI Page 3 EN 12735-1:2001 Foreword This European Standard has been prepared by Technical Committee CEN/TC 133, Copper and copper alloys, the Secretariat of which is held by DIN. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by October 2001, and conflicting national standards shall be withdrawn at the latest by October 2001. Within its programme of work, Technical Committee CEN/TC 133 requested CEN/TC 133/WG 3.1, Copper tubes, to prepare the following standard: m o EN 12735-1, Copper and copper alloys — Seamless, round copper tubes for air-conditioning and refrigeration — Part 1: Tubes for piping systems. This European Standard has been prepared under a mandate given to CEN by the European Commission and the European Free Trade Association, and supports essential requirements of EU Directive(s). c . w x f z b . For relationship with EU Directive(s), see informative annex ZA, which is an integral part of this standard. The attention of the user of this standard is drawn to the fact that national or local regulations or practices might restrict the choice of dimensions and tempers in the application of products conforming to this standard. This is one of a series of European Standards for copper and copper alloy tubes. Other products are specified as follows: EN 1057, Copper and copper alloys — Seamless, round copper tubes for water and gas in sanitary and heating applications. EN 12449, Copper and copper alloys — Seamless, round tubes for general purposes. EN 12450, Copper and copper alloys — Seamless, round copper capillary tubes. EN 12451, Copper and copper alloys — Seamless, round tubes for heat exchangers. EN 12452, Copper and copper alloys — Rolled, finned, seamless tubes for heat exchangers. EN 12735-2, Copper and copper alloys — Seamless, round copper tubes for air-conditioning and refrigeration — Part 2: Tubes for equipment. EN 13348, Copper and copper alloys — Seamless, round copper tubes for medical gases. EN 13349, Copper and copper alloys — Pre-insulated copper tubes with solid covering. EN 13600, Copper and copper alloys — Seamless copper tubes for electrical purposes. According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Czech Republic, Denmark, Finland, France, Germany, Greece, Iceland, Ireland, Italy, Luxembourg, Netherlands, Norway, Portugal, Spain, Sweden, Switzerland and the United Kingdom. w w w Foreword to amendment A1 This document (EN 12735-1:2001/A1:2005) has been prepared by Technical Committee CEN/TC 133 “Copper and copper alloys”, the secretariat of which is held by DIN. This Amendment to the European Standard EN 12735:2001 shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by October 2005, and conflicting national standards shall be withdrawn at the latest by October 2005. This document has been prepared under a mandate given to CEN by the European Commission and the European Free Trade Association, and supports essential requirements of EU Directive 97/23/EC. For relationship with EU Directive 97/23/EC, see informative Annex ZA, which is an integral part of this document. According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom. © BSI 2006 Licensed Copy: Institute Of Technology Tallaght, Institute of Technology, Sun Nov 05 00:55:10 GMT+00:00 2006, Uncontrolled Copy, (c) BSI Page 4 EN 12735-1:2001 Introduction It is recommended that tubes manufactured to this standard are certified as conforming to the requirements of this standard based on continuing surveillance which should be coupled with an assessment of a supplier’s quality management system against EN ISO 9001. 1 Scope m o This European Standard specifies the requirements, sampling, test methods and conditions of delivery for seamless round copper tubes used for refrigeration and air-conditioning piping systems (i.e. piping, connections, repairs). These tubes are supplied in straight lengths in the hard or half-hard tempers, or in coils in the annealed temper. 2 Normative references c . w x f z b . This European Standard incorporates, by dated or undated reference, provisions from other publications. These normative references are cited at the appropriate places in the text and the publications are listed hereafter. For dated references, subsequent amendments to or revisions of any of these publications apply to this European Standard only when incorporated in it by amendment or revision. For undated references, the latest edition of the publication referred to applies (including amendments). EN 1655, Copper and copper alloys — Declarations of conformity. EN 1971, Copper and copper alloys — Eddy current test for tubes. EN 10002-1, Metallic materials — Tensile testing — Part 1: Method of test (at ambient temperature). EN 10204, Metallic products — Types of inspection documents. EN 10234, Metallic materials — Tube — Drift expanding test. EN ISO 6507-1, Metallic materials — Vickers hardness test — Part 1: Test method (ISO 6507-1:1997). NOTE Informative references to documents used in the preparation of this standard, and cited at the appropriate places in the text, are listed in the bibliography. w w w 3 Terms and definitions For the purposes of this standard, the following terms and definitions apply. 3.1 seamless round copper tube hollow semi-finished product, circular in cross-section, made of copper, having a uniform wall thickness, which at all stages of production has a continuous periphery 3.2 mean diameter arithmetical mean of any two diameters normal to each other at the same cross-section of the tube 3.3 deviation from circular form difference between the maximum and minimum outside diameters measured at any one cross-section of the tube © BSI 2006 Licensed Copy: Institute Of Technology Tallaght, Institute of Technology, Sun Nov 05 00:55:10 GMT+00:00 2006, Uncontrolled Copy, (c) BSI Page 5 EN 12735-1:2001 3.4 deviation from concentricity half of the difference between the maximum and minimum wall thicknesses at the same cross-section of the tube 3.5 production batch definite quantity of products of the same form, the same temper and the same cross-sectional dimensions manufactured during the same production sequence under uniform conditions m o 4 Designations 4.1 Material 4.1.1 General c . w x f z b . The material is designated either by symbol or number (see 6.1). 4.1.2 Symbol The material symbol designation is based on the designation system given in ISO 1190-1. NOTE Although the material symbol designation used in this standard might be the same as that in other standards using the designation system given in ISO 1190-1, the detailed composition requirements are not necessarily the same. 4.1.3 Number The material number designation is in accordance with the system given in EN 1412. 4.2 Temper For the purposes of this standard, the following designation, which is in accordance with the system given in EN 1173, applies for the material temper (see Table 1): R... Temper designated by the minimum value of tensile strength requirement for the product with mandatory tensile strength and elongation requirements. 4.3 Product w w w The product designation provides a standardized pattern of designation from which a rapid and unequivocal description of a product is conveyed in communication. It provides mutual comprehension at the international level with regard to products which meet the requirements of the relevant European Standard. The product designation is no substitute for the full content of the standard. The product designation for products to this standard shall consist of: — denomination (copper tube); — number of this European Standard (EN 12735-1); — temper designation (see Table 1); — nominal cross-sectional dimensions: outside diameter ´ wall thickness (see Table 2). The derivation of a product designation is shown in the following example. © BSI 2006 Licensed Copy: Institute Of Technology Tallaght, Institute of Technology, Sun Nov 05 00:55:10 GMT+00:00 2006, Uncontrolled Copy, (c) BSI Page 6 EN 12735-1:2001 EXAMPLE Copper tube conforming to this standard, in temper R290 (hard), nominal outside diameter 28 mm, nominal wall thickness 1,5 mm, shall be designated as follows: 5 Ordering information m o c . w x f z b . In order to facilitate the enquiry, order and confirmation of order procedures between the purchaser and the supplier, the purchaser shall state on his enquiry and order the following information: a) quantity of product required (length, mass); b) denomination (copper tube); c) number of this European Standard (EN 12735-1); d) temper designation (see 4.2 and Table 1); e) nominal cross-sectional dimensions: outside diameter ´ wall thickness (see Table 2); f) nominal length (see 10.2); g) form of delivery (see 10.2); ! h) whether a declaration of conformity is required (see 9.1); i) whether an inspection document is required, and if so, which type (see 9.2)." NOTE 1 It is recommended that the product designation, as described in 4.3 is used for items b) to e). NOTE 2 In addition, the purchaser may also state on the enquiry and the order special requirements, if any. w w w EXAMPLE 1 Ordering details for 500 m copper tube conforming to EN 12735-1, in temper R290 (hard), nominal outside diameter 28 mm, nominal wall thickness 1,5 mm, nominal length 5 m, straight lengths: 500 m Copper tube EN 12735-1 – R290 – 28 ´ 1,5 – 5 m straight lengths EXAMPLE 2 Ordering details for 5 tonnes copper tube conforming to EN 12735-1, in temper R220 (annealed), nominal outside diameter 12 mm, nominal wall thickness 1,0 mm, nominal length 25 m, in coils: 5 tonnes Copper tube EN 12735-1 – R220 – 12 ´ 1,0 – 25 m coiled lengths 6 Requirements 6.1 Composition The composition shall conform to the following requirements: Cu + Ag: min. 99,90 %; 0,015 % £ P £ 0,040 %. This copper grade is designated either Cu-DHP or CW024A. © BSI 2006 Licensed Copy: Institute Of Technology Tallaght, Institute of Technology, Sun Nov 05 00:55:10 GMT+00:00 2006, Uncontrolled Copy, (c) BSI Page 7 EN 12735-1:2001 6.2 Mechanical properties The tensile strength and elongation shall conform to the requirements given in Table 1. The test shall be carried out in accordance with 8.2. Table 1 — Mechanical properties Temper Designation in accordance with EN 1173 Tensile strength Rm Elongation a A MPa % min. min. Common term R220 annealed R250 half-hard R290 hard Hardness (indicative) HV 5 m o c . w x f z b . 220 40 (40 to 70) 250 30 (75 to 100) 290 3 (min. 100) NOTE 1 Hardness figures in parentheses are not requirements of this standard but are given for guidance purposes only. 2 NOTE 2 1 MPa is equivalent to 1 N/mm . a The original gauge length (L0) is calculated proportionally using the formula: L0 = k original cross-sectional area of the test piece ( S 0 ) ; where k has the value 5,65, except that the minimum gauge length used shall be 30 mm. 6.3 Dimensions and tolerances 6.3.1 General The geometrical properties of the tubes are defined by outside diameter, wall thickness and length. NOTE For reference purposes, if DN designation of size for components of a pipework system is required, it can be calculated for tubes to this standard by: Nominal outside diameter (d) - 2 ´ nominal wall thickness (e) DN is defined as a dimensionless whole number which is indirectly related to the physical size, in millimetres, of the bore or outside diameter of the end connections. w w w In cases of dispute, the dimensions shall be measured at a temperature of (23 ± 5) °C. 6.3.2 Nominal dimensions The standardized nominal outside diameters and nominal wall thicknesses are given in Table 2. The recommended lengths are indicated in 10.2. Other designs and dimensions can be agreed between the purchaser and the supplier. © BSI 2006 Licensed Copy: Institute Of Technology Tallaght, Institute of Technology, Sun Nov 05 00:55:10 GMT+00:00 2006, Uncontrolled Copy, (c) BSI Page 8 EN 12735-1:2001 Table 2 — Nominal outside diameters and wall thicknesses Nominal outside diameter d Nominal wall thickness e mm Metric series Imperial series mm mm in 3,18 3,97 4,76 1 6,35 7,94 1 9,52 3 /8 /32 3 /16 /4 5 /16 /8 12,7 1 15,87 5 19,06 3 22,23 25,4 7 /2 /8 18 /4 /8 1 1,5 1,65 2,0 m o 2,5 • • • • • • • • • • • n n n n n n • • • • • • n • n 22 1,25 c . w x f z b . • n 15 • • n n n 28 1 28,57 34,92 1 /8 3 1 /8 41,27 5 1 /8 53,97 1 n n n n 35 108 • n 10 12 76,1 • • • n 8 54 64 1,0 5 6 42 0,8 w w w 2 /8 5 66,67 2 /8 79,37 88,90 92,07 104,80 3 /8 1 3 /2 5 3 /8 1 4 /8 n n n n 1 n n n n n n n n n n n n n n NOTE This table is a first step towards a standard including only metric values. n Available in straight lengths. • Available in coils. © BSI 2006 Licensed Copy: Institute Of Technology Tallaght, Institute of Technology, Sun Nov 05 00:55:10 GMT+00:00 2006, Uncontrolled Copy, (c) BSI Page 9 EN 12735-1:2001 6.3.3 Tolerances on outside diameter The outside diameter shall conform to the tolerances given in Table 3. Table 3 — Tolerances on outside diameter Values in millimetres Nominal outside diameter d Tolerances on nominal diameter Applicable to mean diameter over up to and including all tempers R290 (hard) temper R250 (half-hard) temper 3 18 ± 0,04 ± 0,04 ± 0,09 18 28 ± 0,05 ± 0,06 ± 0,10 28 54 ± 0,06 ± 0,07 ± 0,11 54 76,1 ± 0,07 ± 0,10 ± 0,15 76,1 88,9 ± 0,07 ± 0,15 ± 0,20 ± 0,07 ± 0,20 ± 0,30 88,9 a m o Applicable to a any diameter 108 c . w x f z b . Including deviation from circular form. 6.3.4 Tolerances on wall thickness The tolerance on wall thickness, expressed in percentage of the nominal thickness, as measured at any point, shall conform to the requirements given in Table 4. Table 4 — Tolerances on wall thickness Nominal outside diameter d mm < 18 w w w ³ 18 a Tolerances on wall thickness a e e < 1 mm e ³ 1mm % % ± 10 ± 13 ± 10 ± 15 Including deviation from concentricity 6.3.5 Tolerance on length Lengths shall be equal to or greater than those ordered. 6.3.6 Tolerances of form 6.3.6.1 Deviation from circular form Deviation from circular form for R290 (hard) and R250 (half-hard) temper tubes is included in the tolerances on the outside diameter given in Table 3. Unless otherwise agreed between the purchaser and the supplier, no tolerances on deviation from circular form are applicable to R220 (annealed) temper tubes except coiled tubes with diameters up to and including 16 mm. In this case the maximum deviation from circular form shall be 7 % of the outside diameter. © BSI 2006 Licensed Copy: Institute Of Technology Tallaght, Institute of Technology, Sun Nov 05 00:55:10 GMT+00:00 2006, Uncontrolled Copy, (c) BSI Page 10 EN 12735-1:2001 6.3.6.2 Deviation from concentricity The deviation from concentricity is included in the wall thickness tolerance given in Table 4. 6.3.6.3 Straightness For tubes supplied in R290 (hard) temper in straight lengths, a straightness tolerance may be agreed between the purchaser and the supplier. m o 6.4 Drift expanding No crack, break or tearing of the metal shall be visible to the unaided eye, corrected for normal vision if necessary, when tubes with a nominal outside diameter £ 18 mm in the R220 (annealed) and R250 (half-hard) tempers are tested in accordance with 8.4. 6.5 Surface quality c . w x f z b . The inner and outer surfaces of the tubes shall be clean and smooth. The inner surface of the tubes shall be capable of passing the reference residue test described in 8.5. The 2 residue left after the solvent has evaporated shall not exceed 38 mg/m of the inner surface. 6.6 Freedom from defects The tubes shall be free from defects that could be detrimental to their use. All tubes less than or equal to 42 mm diameter shall be subjected to the eddy current test described in 8.6. For tubes greater than 42 mm diameter, a method of non-destructive testing, if required, shall be agreed between the purchaser and the manufacturer. 7 Sampling For the purposes of demonstrating conformity to the dimensional requirements of this standard and the requirements of 8.1, 8.2 and 8.4, the sampling rate shall be at least one sampling unit for each 3 000 kg or for each production batch whichever is the smaller. NOTE Results may be used from analyses carried out at an earlier stage of manufacturing the product, e.g. at the casting or billets inward stage, if the material identity is maintained and if the quality management system of the manufacturer is certified as conforming to EN ISO 9001. w w w 8 Test methods 8.1 Analysis Analysis shall be carried out on the test samples obtained in accordance with clause 7. The analytical methods used shall be chemical or spectrographic in accordance with appropriate European or international standards. In cases of dispute, the reference method shall be by chemical analysis. 8.2 Tensile test The tensile test shall be carried out in accordance with the method given in EN 10002-1, on test pieces prepared from the test samples obtained in accordance with clause 7. 8.3 Hardness test When required, the Vickers hardness test shall be carried out in accordance with EN ISO 6507-1. © BSI 2006 Licensed Copy: Institute Of Technology Tallaght, Institute of Technology, Sun Nov 05 00:55:10 GMT+00:00 2006, Uncontrolled Copy, (c) BSI Page 11 EN 12735-1:2001 8.4 Drift expanding test The drift expanding test shall be carried out in accordance with EN 10234. The outside diameter of the tube end shall be expanded by 30 % using a conical mandrel with an angle of 45°. 8.5 Residue test Use a minimum length of tube of 1 500 mm to perform the test. m o Close one end of the tube test piece and pour in suitable solvent, to one eighth of its capacity. Close the other end of the test piece and agitate the tube, in order to clean thoroughly the whole of its internal surface. Open one end of the tube and pour the solvent into a clean beaker. Open the other end to ensure all solvent is removed. Evaporate the solvent and dry the beaker in an oven at 100 °C to 110 °C for 10 min. Cool the beaker in a desiccator and weigh it. c . w x f z b . Carry out a blank test using the same quantity of solvent. Subtract the value obtained in the blank test from the value obtained in the residue test and calculate the mass per unit area of internal surface. The quantity of solvent used may vary with the size of the tube being examined. The quantity of solvent used for the blank test shall be the same as that used for the actual examination of the tube sample. For a reference test trichlorethylene shall be used. NOTE For routine controls in the course of quality assurance procedures, other methods may be used as an alternative. 8.6 Eddy current test The test shall be carried out in accordance with EN 1971. The reference standard tube shall contain holes produced from the drill diameters in Table 5. Table 5 — Drill diameters for reference standard tube Dimensions in millimetres Nominal outside diameter d over w w w 3 26 Drill diameter up to and including max. 26 0,8 42 1,2 Signals produced by reference standard tubes set the sorting limits for acceptance or rejection. Tubes containing defects which produce signals equal to or greater than the sorting limit shall be rejected. 8.7 Retests In the event that the tube sample fails to meet the test requirements, the batch represented by the tube sample or, in the case of continuous production, all tubes manufactured since the previous check, shall be placed in a bond. Further samples shall be taken from the bonded tubes at a sampling rate four times more frequent than specified in clause 7. If any of the retest samples fail to meet the specification requirements, the tubes represented by the samples shall be deemed not to meet the requirements of this standard and shall be rejected. If all the retest samples meet the requirements, the tubes represented by the samples shall be deemed to meet the requirements of this standard. © BSI 2006 Licensed Copy: Institute Of Technology Tallaght, Institute of Technology, Sun Nov 05 00:55:10 GMT+00:00 2006, Uncontrolled Copy, (c) BSI Page 12 EN 12735-1:2001 9 Declaration of conformity and inspection documentation 9.1 Declaration of conformity !When requested by the purchaser [see 5 h)] and agreed with the supplier, the supplier shall issue for the products the appropriate declaration of conformity in accordance with EN 1655." 9.2 Inspection documentation m o ! When requested by the purchaser [see 5 i)] and agreed with the supplier, the supplier shall issue for the products the appropriate inspection document in accordance with EN 10204. NOTE When ordering material for pressure equipment applications, the equipment manufacturer has the obligation to request appropriate inspection documentation according to EN 10204." c . w x f z b . 10 Packaging, marking and form of delivery 10.1 Packaging and marking Each tube shall be capped, plugged or otherwise closed at both ends so as to maintain the internal cleanliness of the tube under normal conditions of handling and storage. NOTE Plug design should be such to prevent the plug from being forced into the tube bore beyond its depth. The tubes shall be packaged in such a way that they are effectively protected in normal transport and handling conditions. The tubes shall be packaged in uniform batches, i.e. of the same dimensions and temper, and each package shall indicate at least the following information in a legible and indelible manner: — number of this standard (EN 12735-1); — nominal cross-sectional dimensions: outside diameter ´ wall thickness; — quantity; — temper; w w w — manufacturer’s identification mark. 10.2 Form of delivery Coiled tubes are usually supplied in 25 m or 50 m lengths. Straight tubes are usually supplied in 3 m, 5 m or 6 m lengths. © BSI 2006 Licensed Copy: Institute Of Technology Tallaght, Institute of Technology, Sun Nov 05 00:55:10 GMT+00:00 2006, Uncontrolled Copy, (c) BSI Page 13 EN 12735-1:2001 ! Annex ZA (informative) Relationship between this European Standard and the Essential Requirements of EU Directive 97/23/EC m o This European Standard has been prepared under a Mandate given to CEN by the European Commission and the European Free Trade Association to provide a means of conforming to Essential Requirements of the New Approach Directive 97/23/EC. Once this standard is cited in the Official Journal of the European Communities under that Directive and has been implemented as a national standard in at least one Member State, compliance with the clauses of this standard given in Table ZA.1 confers, within the limits of the scope of this standard, a presumption of conformity with the corresponding Essential Requirements of that Directive and associated EFTA regulations. c . w x f z b . For this harmonized supporting standard for materials, presumption of conformity to the Essential Requirements of the Directive is limited to technical data of the material in the standard and does not presume adequacy of the material to specific equipment. Consequently the technical data stated in the material standard should be assessed against the design requirements of the specific equipment to verify that the Essential Requirements of the Pressure Equipment Directive (PED) are satisfied. Table ZA.1 — Correspondence between this European Standard and Directive 97/23/EC Clause(s)/ subclause(s) of this EN Subject 6.2 Material properties 9.2 Conformity of material and manufacturer's certified documentation Qualifying remarks/Notes Annex I 4.1(a) of the Directive Annex I 4.3 of the Directive NOTE Brittle fracture prevention: Copper, having a face-centred cubic crystal structure, does not suffer a transition from ductile to brittle failure like some other materials. w w w WARNING — Other requirements and other EU Directives may be applicable to the product(s) falling within the scope of this standard." © BSI 2006 Licensed Copy: Institute Of Technology Tallaght, Institute of Technology, Sun Nov 05 00:55:10 GMT+00:00 2006, Uncontrolled Copy, (c) BSI Page 14 EN 12735-1:2001 Bibliography In the preparation of this European Standard, use was made of a number of documents for reference purposes. These informative references are cited at the appropriate places in the text and the publications are listed hereafter. EN 1173, Copper and copper alloys — Material condition or temper designation. m o EN 1412, Copper and copper alloys — European numbering system. EN ISO 9001, Quality management systems - Requirements (ISO 9001:2000). ISO 1190-1, Copper and copper alloys — Code of designation — Part 1: Designation of materials. w w w © BSI 2006 c . w x f z b . Licensed Copy: Institute Of Technology Tallaght, Institute of Technology, Sun Nov 05 00:55:10 GMT+00:00 2006, Uncontrolled Copy, (c) BSI m o w w w c . w x f z b . blank Licensed Copy: Institute Of Technology Tallaght, Institute of Technology, Sun Nov 05 00:55:10 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BS EN 12735-1:2001 BSI — British Standards Institution BSI is the independent national body responsible for preparing British Standards. It presents the UK view on standards in Europe and at the international level. It is incorporated by Royal Charter. Revisions British Standards are updated by amendment or revision. Users of British Standards should make sure that they possess the latest amendments or editions. m o It is the constant aim of BSI to improve the quality of our products and services. We would be grateful if anyone finding an inaccuracy or ambiguity while using this British Standard would inform the Secretary of the technical committee responsible, the identity of which can be found on the inside front cover. Tel: +44 (0)20 8996 9000. Fax: +44 (0)20 8996 7400. c . w x f z b . BSI offers members an individual updating service called PLUS which ensures that subscribers automatically receive the latest editions of standards. Buying standards Orders for all BSI, international and foreign standards publications should be addressed to Customer Services. Tel: +44 (0)20 8996 9001. Fax: +44 (0)20 8996 7001. Email: [email protected]. Standards are also available from the BSI website at http://www.bsi-global.com. In response to orders for international standards, it is BSI policy to supply the BSI implementation of those that have been published as British Standards, unless otherwise requested. Information on standards BSI provides a wide range of information on national, European and international standards through its Library and its Technical Help to Exporters Service. Various BSI electronic information services are also available which give details on all its products and services. Contact the Information Centre. Tel: +44 (0)20 8996 7111. Fax: +44 (0)20 8996 7048. Email: [email protected]. Subscribing members of BSI are kept up to date with standards developments and receive substantial discounts on the purchase price of standards. For details of these and other benefits contact Membership Administration. Tel: +44 (0)20 8996 7002. Fax: +44 (0)20 8996 7001. Email: [email protected]. w w w Information regarding online access to British Standards via British Standards Online can be found at http://www.bsi-global.com/bsonline. Further information about BSI is available on the BSI website at http://www.bsi-global.com. Copyright Copyright subsists in all BSI publications. BSI also holds the copyright, in the UK, of the publications of the international standardization bodies. Except as permitted under the Copyright, Designs and Patents Act 1988 no extract may be reproduced, stored in a retrieval system or transmitted in any form or by any means – electronic, photocopying, recording or otherwise – without prior written permission from BSI. BSI 389 Chiswick High Road London W4 4AL This does not preclude the free use, in the course of implementing the standard, of necessary details such as symbols, and size, type or grade designations. If these details are to be used for any other purpose than implementation then the prior written permission of BSI must be obtained. Details and advice can be obtained from the Copyright & Licensing Manager. Tel: +44 (0)20 8996 7070. Fax: +44 (0)20 8996 7553. Email: [email protected].