Transcript
Including Scene Capable Dimmer intoZ-Wae ® Networ:Restore Power: Restorepoweratcircuitbreakerorfuse. Installation is complete. D) ThePrimaryProgrammer/ControllerwillassignanodeIDnumber(Name)forthismodule. NOTE: ThisIDnumber(Name)willbestoredinthecontrollerlibrarytobeusedforfuturereference. NOTE: Youmayeditthenameofthisdeviceatthistime. E) Te dimmer is now installed inte networ.NOTE: IfadimmerhasbeensuccessfullyIncludedinthenetworkandtheusertriestoIncludeitagainwithoutrstexcludingitfromthenetwork,themodulewillretaintherstnodeIDithadreceivedandignorethesecond. Testing your Dimmer prior to mounting inwall box: LIMITED 5 YEAR WARRANTY AND EXCLUSIONS LevitonwarrantstotheoriginalconsumerpurchaserandnotforthebenetofanyoneelsethatthisproductatthetimeofitssalebyLevitonisfreeofdefectsinmaterialsandworkmanshipundernormalandproperuseforveyearsfromthepurchasedate.Leviton’sonlyobligationistocorrectsuchdefectsbyrepairorreplacement,atitsoption,ifwithinsuchveyearperiodtheproductisreturnedprepaid,withproofofpurchasedate,andadescriptionoftheproblemto Leiton Manuacturing Co., Inc., Att: Quality Assurance Department, 59-25 Little Nec Parway, Little Nec, New Yor 11362-2591. Thiswarrantyexcludesandthereisdisclaimedliabilityforlaborforremovalofthisproductorreinstallation.Thiswarrantyisvoidifthisproductisinstalledimproperlyorinanimproperenvironment,overloaded,misused,opened,abused,oralteredinanymanner,orisnotusedundernormaloperatingconditionsornotinaccordancewithanylabelsorinstructions. Tere are no oter or implied warranties o any ind, including mercantability and ftness or a particular purpose ,butifanyimpliedwarrantyisrequiredbytheapplicablejurisdiction,thedurationofanysuchimpliedwarranty,includingmerchantabilityandtnessforaparticularpurpose,islimitedtoveyears. Leiton is not liable or incidental, indirect, special, or consequential damages, including witout limitation, damage to, or loss o use o, any equipment, lost sales or profts or delay or ailure to perorm tis warranty obligation. Theremediesprovidedhereinaretheexclusiveremediesunderthiswarranty,whetherbasedoncontract,tortorotherwise. ãRestorepoweratcircuitbreakerorfuse.ãPresspaduntillocatorlightisOFF.LightsshouldturnON.IflightsdonotturnON,presstherighthalfofDIM/BRIGHTbaruntilthelightsbrighten. I ligts still do not turn ON, reer to teTROUBLEShOOTING section. NOTES: ãIfusinganon-LevitonProgrammer/Controller,refertotheProgrammer/ControllerinstructionsheetforIncludingadevice.ãIfusingtheVRCPG'sInstallChecklistfeature,godirectlytoStepB. A) IfusingaLevitonZ-Wave ® Programmer/ Controller,Cat.No.VRCPG,presstheMenubuttonandscrolldowntoSystemSetup.PressthecenterbuttontoselectSystemSetupMenu.ChooseAdvancedSettings.PressthecenterbuttontoselectNetwork. B) Whilestandingclosetothemodule(approx.2-5ft),pressthecenterbuttonto<Include>deviceinthenetwork. NOTE: Onlyonedevicemaybeincludedatatime. DO NOT putmultipledevicesintotheInclusionmodeatanytime. C) WhiletheProgrammer/ControllerisintheInclusionmodeandtheLocatorLEDisONonthedimmer,pushthepushpadtoturnONthedimmer.TheProgrammer/ControllerwillverifyinclusionandthelocatorLEDwillturnOFFonthedimmer.IfthedimmerisashingAmberwhileintheInclusionmode,theProgrammer/Controllerisstilltryingtocommunicatewiththedimmer.Waituntilthedevicestopsashing,thenpresspushpad. NOTE: IfthelocatorLEDonthedimmerturnssolidRedwhileincluding,therehasbeenacommunicationerror.RefertoTroubleshootingsection. DI-000-VRI10-02A 2008©LevitonMfg.Co.,Inc.ProtectedunderU.S.PatentNumber6,388,399andpatentspending andlicensedunderU.S.PatentsNumbers5,905,442,and5,982,103 Programmer/ControllerCat. No. vRCPG MenuButton 1 ON 2 ON 3 ON 4 ONOFFOFFOFFOFF CenterButton ã Ligts Flicering -Lamphasabadconnection.-Wiresnotsecuredrmlyunderterminalscrewsofdimmer and/orremote.-Localswitch,ONã Ligt does not turn ON and Locator LED does not turn ON -Circuitbreakerorfusehastripped.-Lampisburnedout.-LampNeutralconnectionisnotwired.-Conrmthatthedeviceisbeingsuppliedfroma120V,60HzACsourceONLY.-Conrmthatunitisprogrammedproperly.Repeat“TOINSTALL”sectiontoverifythatithasbeenincludedintheZ-Wave™network.ã Intermittent dimmer operation -Minimumloadisunder40W.-ConrmthattheLoadbeingcontrolleddoesnotexceedthe1000Wdimmerlimit.ã Remote does not operate ligts -Ensurethattotalwirelengthdoesnotexceed300ft. TROUBLEShOOTING For additional inormation, contact Leiton’s Teclineat 1-800-824-3005 or isit Leiton’s website atwww.viziaRFplus.com NOTE: ThelocatorlightwillilluminatewhentheloadisintheOFFpositiontofacilitateaccessinthedark. NOTE: Ifusingthedimmerina3-wayapplication,thelightswillturnONatbrightnesssetondimmer’sDIM/BRIGHTbar.Thelightingcanbecontrolledfromeitherthedimmerortheremotelocation. Pus Pad (Deault settings)Turn ON rom OFF position: Tap–LightsturnONtopresetlevel. PressandHold–LightsturnONtofullbright. Turn OFF rom ON position: Tap–LightsturnOFF. LED BrigtnessDisplayDIM/BRIGhTBarPusPadLocatorLigt OPERATION Installationmaynowbecompletedbytighteningmountingscrewsintowallbox.Attachwallplate. Dimmer Mounting: TURN OFF POWER ATCIRCUIT BREAkEROR FUSE. Step 7Step 6 NOTE: ItisveryimportanttoaccuratelyExcludedevicesfromthenetworkwhenmovingorremovingadevicefromaZ-Wave ® network.ThisensuresthatallinformationhasbeenremovedfromyourPrimaryProgrammer/Controller’sinformationtableandisnotcountedontobeapartofthemeshnetwork. A) IfusingaLevitonZ-Wave ® Programmer/Controller,Cat.No.VRCPG,presstheMenubuttonandscrolldowntoSystemSetup.PressthecenterbuttontoselectSystemSetupMenu.ChooseAdvancedSettings.PressthecenterbuttontoselectNetwork. B) Whilestandingclosetothedimmer,pressthecenterbuttonto<Exclude>devicefromthenetwork.WhiletheProgrammer/ControllerisintheExclusionmodeandthelocatorLEDisONonthedimmer,pressthepushpadonthedimmer.TheProgrammer/ControllerwillverifyExclusionandthelocatorLEDwillturnOFFonthedimmer.IfthedimmerisashingAmberwhileintheExlusionmode,theProgrammer/Controllerisstilltryingtocommunicatewiththedimmer.Waituntilthedevicestopsashing,thenpressthepushpad. Factory Default: Ifyourdimmerisnotresponding,oryouareunabletocontrolitafteryouhavetriedtoInclude/Excludeitmultipletimes,itmaybenecessarytoresetthedimmertoitssrcinalfactorysettings.Toaccomplishthis,proceedasfollows:ãOnthedimmer,engageheair-gapswitch (refer to Operationsection) andwait5seconds.PresspushpadbackintoframeandholdpushpaduntilthelocatorLEDturnsAmberandthenturnsRed.Thedimmerisnowreset.Oncethedimmerisreset,itwillbenecessarytoRe-Includeittoanetworkbeforeitcanbeused. CAUTION: SETTINGADEVICETOAFACTORYDEFAULTDOESNOTEXCLUDETHATDEVICEFROMANETWORK.THEEXCLUSIONPROCEDUREMUSTSTILLBEFOLLOWEDTOREMOVETHEDEVICEFROMTHEPRIMARYCONTROLLER’SINFORMATIONTABLE.FAILURETODOSOMAYRESULTINASYSTEMTHATISSLOWTORESPOND,ORMAYFAILTORESPONDTOSOMEDEVICES. Step 9 Excluding Dimmer rom Networ: Step 8 NOTE: Dresswireswithabendasshownindiagraminordertorelievestresswhenmountingdevice. ã Positionallwirestoprovideroominoutletwallboxfordevice. ã Ensurethattheword“TOP”isfacingupondevicestrap. ã Partiallyscrewinmountingscrewsinwallboxmountingholes. Step 5 A-2) TheLocatorLEDwillblink2timespersecondtoindicatethedeviceisinProgramMode A-2, Minimum Brigtness Leel . Tochangethe Minimum Brigtness Leel from1-50%,usetheDIM/BRIGHTBar.Thelightoutputwillreecttheminimumbrightnesslevelselected.BytappingthePushPadthissettingwillautomaticallybesavedandthedevicewilladvancetothenextprogrammingmode, A-3 . A-3) TheLocatorLEDwillblink3timespersecondtoindicateProgram Mode A-3, Preset ON Leel .Tochangethecurrent Preset ONLeel from1-100%,usetheDIM/BRIGHTBar.Ifthisfeatureisnotdesired,pressandholdthe left halfoftheDIM/BRIGHTBar ( v ) untilnoLEDislit(defaultsetting).BytappingthePushPadthissettingwillautomaticallybesavedandthedevicewill exitProgrammingModeA. Program Mode B To enter Program Mode B: PressandholdthePushPadandthenthe left halfofthe DIM/BRIGHTBar( v )for5secondsuntiltheLocatorLEDandrightmostLED(LED7)begintoblink. B-1) UponreleasingthePushPadandthe left halfofthe DIM/BRIGHTBar( v ),theLocatorLEDwillcontinuetoblinkoncepersecondindicatinghedimmerisinProgramMode B-1, ONFade Rate .Tochangethe ON Fade Rate ,usetheDIM/BRIGHTBartomovetheLEDtothedesiredpresetlevelaccordingto CartB .BytappingthePushPadthissettingwillautomaticallybesavedandthedevicewilladvancetothenextprogrammingmode, B-2 . B-2) TheLocatorLEDwillblink2timespersecondtoindicateProgram Mode B-2, OFF Fade Rate .Tochangethe OFF Fade Rate ,usetheDIM/BRIGHTBartomovetheLEDtothedesiredpresetlevel according to Cart B .BytappingthePushPadthissettingwillautomaticallybesavedandthedevicewilladvancetothenextprogrammingmode, B-3 . LED BrightnessDisplay 1 2 3 4 5 6 7 Defnition o A Modes A-1) EnergySave:Setsthemaximumbrightnesslevelforenergysavings. A-2) MinimumBrightnessLevel:Setstheminimumdimminglevel. A-3) PresetONLevel:Setstheturnonbrightnesslevelregardlessoftheprevioussetlightlevel(formerlyDimLock). Defnition o B ModesB-1) ONFadeRate:SetstheamountoftimeinsecondsittakesthelightstoturnONtomaximumbrightness. B-2) OFFFadeRate:SetstheamountoftimeinsecondsittakesthelightstoturnOFFfrommaximumbrightness. B-3) LEDOptions:SetsthetimeperiodinsecondstheLocatorLEDandBrightnessdisplaywillstayonbeforeextinguishing. Defnition o LEDs LeftmostLED=LED1RightmostLED=LED7 NOTES: ãThedevicewillexitprogrammingmodeafter3minutesofinactivity.ãPressingthepushpadatanytimeduringprogrammingwilladvancethedevicetothenextprogrammingmode. ADvANCED PROGRAMMING FEATURES Program Mode A To enter Program Mode A: PressandholdthePushPadandthenthe right halfofthe DIM/BRIGHTBar ( ^ ) for5secondsuntiltheLocatorLEDandleftmostLED(LED1)begintoblink. A-1) UponreleasingthePushPadandthe right halfoftheDIM/BRIGHTBar ( ^ ) ,theLocatorLEDwillcontinuetoblinkoncepersecondandtherightmostLEDwillilluminatetodisplaythedeviceisinProgramMode A-1, Energy Sae .Thedefaultenergysavemodeis100%i.e.fullbright.Tochange the Energy Sae level,usetheDIM/BRIGHTBartomovethecorrespondingLEDtothedesireddiscretepresetlevel according to Cart A .BytappingthePushPadthissettingwillautomaticallybesavedandthedevicewilladvancetothenextprogrammingmode, A-2 . B-3) TheLocatorLEDwillblink3timespersecondtoindicateProgram Mode B-3, LED Options .Tochangethe LED Options settings,usetheDIM/BRIGHTBartomovetheLEDtothedesiredpresetsettingaccordingtothe Cart B-3 .BytappingthePushPadthissettingwillautomaticallybesavedandthedevicewillexitProgramming ModeB. LED LED 1LED 2 (Default)LED 3LED 4LED 5LED 6LED 7 FADE ON 0 seconds (instant)0.5 seconds1.5 seconds3.0 seconds6.0 seconds10 seconds25 seconds0 seconds (instant)0.5 seconds1.5 seconds3.0 seconds6.0 seconds10 seconds25 seconds FADE OFF Cart B When indicatorlight is at LED # 7654321 Light output is at 100%97%95%90%85%80%75% Energy consumptionsavings amounts to 0%5%8%11%14%17%20% Cart ACart B-3 LED LED 1LED 2LED 3LED 4LED 5LED 6LED 7 LOCATOR LED TIMEOUT ActiveActiveActiveActiveTurns off 5 sec. after useTurns off 5 sec. after useTurns off 5 sec. after use LED BRIGHTNESS DISPLAY OPTIONS ActiveTurns off 5 sec. after useActiveTurns off 5 sec. after useLED Bar activeLED Bar turns off 5 sec. after useLED Bar turns off 5 sec. after use vRCPGProgrammer/ControllerNOTE: Remotemustbeincloseproximitytodimmerwhenincludinginnetwork. DIM/BRIGhT BarBRIGhTEN: PressrighthalfofDIM/BRIGHTBar–Lightsbrightentodesiredlevel. DIM: PresslefthalfofDIM/BRIGHTBar–Lightsdimtodesiredlevel. IfyoucontinuetoholdthelowerhalfoftheDIM/BRIGHTBar,thelightswillDIMtominimumlevelandthenturnOFF. NOTE: WhenlightsareOFFyoucanchangethelightlevelthatthelightswillturnONtousingtheDIM/BRIGHTBar.Ifthereisapoweroutage,whenthepowerisrestoredthelightswillreturntothelastsettingbeforethepowerinterruption. Air-Gap Switc: Onthedimmeronly, engage theair-gapswitchbygentlypressingthetopofthepushpaduntilthebottomliftscompletelyoutoftheframeandaclickis heard (reer to Figure) .LEDswillturnOFF. Thiswillcutpowertothexturetoreplacethebulb.Afterservicingiscomplete,pushthepushpadbackfornormaloperation. Cleaning: Cleanwithadampcloth. DO NOT usechemicalcleaners. Gently press topo pus pad ThisequipmenthasbeentestedandfoundtocomplywiththelimitsforaClassBDigitalDevice,pursuanttoPart15oftheFCCRules.Theselimitsaredesignedtoprovidereasonableprotectionagainstharmfulinterferenceinaresidentialinstallation.Thisequipmentgenerates,uses,andcanradiateradiofrequencyenergyand,ifnotinstalledandusedinaccordancewiththeinstructions,maycauseharmfulinterferencetoradiocommunications.However,thereisnoguaranteethatinterferencewillnotoccurinaparticularinstallation.Ifthisequipmentdoescauseharmfulinterferencetoradioortelevisionreception,whichcanbedeterminedbyturningtheequipmentOFFandON,theuserisencouragedtotrytocorrecttheinterferencebyoneormoreofthefollowingmeasures:ãReorientorrelocatethereceivingAntenna.ãIncreasetheseparationbetweentheequipmentandthereceiver.ãConnecttheequipmentintoanoutletonacircuitdifferentfromthattowhichthereceiverisconnected.ãConsultthedealeroranexperiencedradio/tvtechnicianforhelp. FCC COMPLIANCE STATEMENT