SUPPLY NETWORK ANALYZER CVM-LC (Ver 6.11 and higher) INSTRUCTION MANUAL ( M98170301-03 / 03A )  CIRCUTOR S.A. ----- Supply network analyzer CVM-LC ------ User's manual --- Page No. 1 CONTENTS 1.2.3.4.- page DELIVERY SPOT CHECK .......................................................................................................... 2 MAIN FEATURES ....................................................................................................................... 3 MODELS ...........

   EMBED


Share

Transcript

    SUPPLY NETWORK ANALYZER CVM-LC (Ver 6.11 and higher) INSTRUCTION MANUAL ( M98170301-03 / 03A )    CIRCUTOR S.A.    ----- Supply network analyzer CVM-LC ------ User's manual --- Page No. 1 CONTENTS   page   1.-   DELIVERY SPOT CHECK..........................................................................................................2   2.-   MAIN FEATURES.......................................................................................................................3   3.-   MODELS.....................................................................................................................................5   4.-   INSTALLATION AND START-UP...............................................................................................5   4.1.- Installation.....................................................................................................................6   4.2.- CVM-LC connection terminal arrangement (power supply connection terminal)...............................8   4.3.- Connection drawing for the CVM-LC :...........................................................................9   5.-   OPERATION MODE.................................................................................................................13   6.-   SET-UP PROCEDURE.............................................................................................................15   6.1.- Phase-to-Phase or Phase-to-Neutral voltages............................................................16   6.2.- Voltage display mode..................................................................................................16   6.3.- Voltage Transformer Primary......................................................................................17   6.4.- Voltage Transformer Secondary.................................................................................18   6.5.- Current Transformer Primary......................................................................................18   6.6.- Setting power demand utility screens..........................................................................19   6.7.- Initial screen setting.....................................................................................................20   6.8.- Setting of the display shutdown time...........................................................................20   6.9.- Clearing energy counters............................................................................................21   6.10.- THD or D setting........................................................................................................22   7.-   SPECIFICATIONS....................................................................................................................23   8.-   SAFETY CONSIDERATIONS...................................................................................................25   1.-   M...............................................................................................................................................25   9.-   AINTENANCE...........................................................................................................................25   10.-   TECHNICAL SERVICE.............................................................................................................25   11.-   APPENDIX A: Second SET-UP of the CVM-LC......................................................................26   11.1.- SET-UP locking or unlocking....................................................................................26      ----- Supply network analyzer CVM-LC ------ User's manual --- Page No. 2 1.- DELIVERY SPOT CHECK This manual is issued to help all the CVM-LC users to install and use it inorder get the best from it. After receiving the unit, please check the following points:(a) Does this device correspond to your order specifications?(b) Check if any damage was done during the shipment process.(c) Verify that it includes the correct instruction manual.The manual you hold in your hands contains information and warningsabout the CVM-LC that the user should respect in order to guaranteea proper operation of all the instrument functions and keep its safetyconditions.   Before powering the instrument for the first time, verify following points:(a) Power supply: see rear part of your CVM-LC  Standard : 230 V a.c. Single-phase, Frequency: 50 ... 60 Hz    SDC Model : 24 .... 120 V d.c.    Other supply voltages, on request.(b) Maximum measuring voltage:  Standard : 300 V a.c. phase-neutral / 520 V a.c. between phases      Other models: on request   CVM-LC - measuring 110V: 110 V a.c. phase-to-neutral /190 V a.c. phase-to-phase CVM-LC - measuring 500V: 500 V a.c. phase-to-neutral /866 V a.c. phase-to-phase  (c) Maximum measurable current: Current transformer of In / 5 A a.c.    ----- Supply network analyzer CVM-LC ------ User's manual --- Page No. 3 2.- MAIN FEATURES The CVM-LC power meter is a programmable measuring instrument, offeringseveral operation possibilities selectable in its SET-UP option. Before powersupplying the instrument, read the CONNECTIONS and SET-UP sections andchoose the most suitable operation mode for getting your desired data. CVM-LC L1L2L3  The CVM-LC is an instrument which measures, calculates and displays all themain electrical parameters at any electrical network (balanced or not). Themeasuring is true RMS value, through three a.c. voltage inputs and three a.c. currentinputs (from Current Transformers .../ 5A).