Preview only show first 10 pages with watermark. For full document please download

Weibull

weibull

   EMBED


Share

Transcript

Table of Contents THE USE OF WEIBULL IN DEFECT DATA  ANALYSIS INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Information Sources . . . . . . . . . . . . . . . . . . . . . . . . . . 1  Application to Sampled Defect Data . . . . . . . . . . . . . . . . . 1 DATA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Quality of Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Quantity of Data . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 THE TH E ME MECH CHAN ANIC ICS S OF WE WEIB IBUL ULL L AN ANAL ALYS YSIS IS . . . . . . . . . . . . . . 4 The Value of Analysis . . . . . . . . . . . . . . . . . . . . . . . . . 4 Eval Ev alua uati ting ng th thee We Weib ibul ulll Par aram amet eter erss . . . . . . . . . . . . . . . . . . 5 INTE IN TERP RPRE RETA TATI TION ON OF WE WEIB IBUL ULL L OU OUTP TPU UT . . . . . . . . . . . . . . 7 Concept of Hazard . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Scal Sc alee Pa Para rame mete terr or Ch Char arac acte teri rist stic ic LI LIfe fe . . . . . . . . . . . . . . . . 10 Loccat Lo atio ion n Pa Para rame mete terr or Mi Mini nimu mum m Li Life fe . . . . . . . . . . . . . . . . 11 PRACTICAL DIFFICULTIES WITH WEIBULL PLOTTING. . . . . . . 13 Scatter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 13 Extrapolation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Multi-Modal Failures . . . . . . . . . . . . . . . . . . . . . . . . . 13 Confidence Limits . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Censoring of Sample Data . . . . . . . . . . . . . . . . . . . . . . . 15 COMPARISON WITH HAZARD PLOTTING . . . . . . . . . . . . . . 16  CONCLUSIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 TWO CYCLE WEIBULL PAPER. . . . . . . . . . . . . . . . . . 18 PROGRE PRO GRESSI SSIVE VE EXA EXAMPL MPLE E OF WEIB WEIBULL ULL PLO PLOTTI TTING NG . . . . . . 20 ESTIMA EST IMATIO TION N OF WEI WEIBUL BULL L LOCA LOCATION TION PAR PARAME AMETER. TER. . . . 31 EXAMPLE OF A 3-PARAMETER WEIBULL PLOT. . . . . . . . . . 32 THE EFFECT OF SCATTER. . . . . . . . . . . . . . . . . . . . . . 37 95% CONFIDENCE LIMITS FOR WEIBULL. . . . . . . . . . . . . 39  WEIBULL PLOT OF MULTIPLY-CENSORED DATA . . . . . . . . 42 EXAMPLE OF A 3-PARAMETER WEIBULL PLOT. . . . . . . . . . 32 THE EFFECT OF SCATTER. . . . . . . . . . . . . . . . . . . . . . 37 95% CONFIDENCE LIMITS FOR WEIBULL. . . . . . . . . . . . . 39  WEIBULL PLOT OF MULTIPLY-CENSORED DATA . . . . . . . . 42 THE USE OF WEIBULL IN DEFECT DATA ANALYSIS THE USE OF WEIBULL IN DEFECT DATA  ANALYSIS 1 INTRODUCTION These notes give a brief introduction to Weibull analysis and its potential contribution to equipment equipme nt maintenance and lifing policies. Statisti Statistical cal terminology terminology has been avoided wherever possible possible and those terms which are used are explained, albeit albeit briefly. Weibul Weibulll analysis origin ori ginate ated d fro from m a pap paper, er, Refe Referen rence ce 1, pub publish lished ed in 195 1951 1 by a Swe Swedis dish h mec mechan hanica icall eng enginee ineer, r, Pro Pro-fessor fess or Wal Walodd oddii Wei Weibul bull. l. His ori origin ginal al pap paper er did lit little tle mor moree tha than n pro propos posee a mult multi-p i-para aramete meterr dis dis-tribution, but it became widely appreciated and was shown by Pratt and Whitney in 1967 to have some application to the analysis of defect data. 1.1 1. 1 Info In form rmat atio ion n So Sour urce cess The de The defin finiti itive ve st stat atist istic ical al te text xt on Wei Weibu bull ll is ci cited ted at Re Refer ferenc encee 2, an and d pu publ blic icat atio ions ns cl clos oser er to th thee work wo rkingleve inglevell ar aree gi give ven n at Re Refer ferenc encee 3 an and d 4. A se sett of Br Briti itish sh St Stan anda dard rds, s, BS 57 5760 60 Pa Part rtss 1 to 3 co covvering a broad spectrum spectrum of reliability reliability activities activities are being issued. Part 1 on Reliability Reliability Program gr amme me Ma Mana nage geme ment nt wa wass iss issued ued in 19 1979 79 bu butt is of li littl ttlee va valu luee he here re ex exce cept pt fo forr it itss co comm mment entss on the diff difficu icultie ltiess of obt obtain aining ing ade adequa quate te dat data. a. Par Partt 2, Refe Referen rence ce 5, con contai tains ns val valuab uable le gui guidan dance ce for thee ap th appl plic icat atio ion n of Wei Weibu bull ll an anal alys ysis is al alth thou ough gh th this is ma may y be di diff ffic icult ult to ex extr trac act. t. The The th thir ird d of th thee Standa Sta ndard rd con contai tains ns aut authen hentic tic pra practi ctical cal exa exampl mples es ill illustr ustrati ating ng the pri princip nciples les esta establi blishe shed d in Par Parts ts 1 an and d 2. On Onee fu furt rthe herr so sour urce ce of in info form rmat atio ion n is an I Me Mech ch E pa pape perr by Sh Sher erwi win n an and d Le Lees es at Re Refe ferrencee 6. Pa enc Part rt 1 of th this is pa pape perr is a go good od re revi view ew of cu curr rren entt We Weib ibul ulll th theo eory ry an and d Pa Part rt 2 pr prov ovid ides es so some me insight into the practical problems inherent in its use. 1.2 Applic App licati ation on to Sam Sampled pled Def Defect ect Dat Data a It is im impo port rtan antt to de defi fine ne th thee co conte ntext xt in wh whic ich h th thee fo foll llow owing ing Wei Weibu bull ll an anal alysi ysiss ma may y be us used ed.. Al Alll that is stated subsequently is applicable to sampled defect data. This is a very different situation to that which exists on, say, the RB-211 for which Rolls Royce has a complete data base. They Th ey kno know w at an any y tim timee th thee li life fe di distr strib ibuti ution on of al alll th thee in in-s -ser ervi vice ce eng engin ines es an and d th their eir co comp mpon onen ents, ts, and an d th thei eirr an anal alys ysis is ca can n be do done ne fr from om a kn know owle ledg dgee of th thee uti utili liza zatio tions ns at failure an and d th thee cu curr rrent ent utilisa util isatio tion n for all the non-failed com compon ponents ents.. The Their ir for form m of Weib Weibull ull ana analysi lysiss is uni unique que to thi thiss situation situati on of total visibility. visibility. It is assumed here, here, however, that most organisatio organisations ns are not in this th is fo fort rtun unat atee po posit sitio ion; n; th their eir da data ta wi will ll at be best st be of so some me re repr prese esenta ntativ tivee sa samp mple le of th thee fa fail ilur ures es which whi ch ha have ve occ occurr urred, ed, and andof of util utiliza izatio tion n of unfa unfailedunits. iledunits. It is stre stressedtoo ssedtoo hig highly hly,, tho though ugh,, tha thatt Warwick Manufacturing Group  Revision date: 6 December, 2004 20 04 1 THE USE OF WEIBULL IN DEFECT DATA ANALYSIS life of unfailed units must units  must be known if a realistic estimate of lifetimes to failure is to be made, and, therefore, data must be collected on unfailed units in the sample. 2 D ATA The basic elements in defect data analysis comprise:  a population, population, from from which which some sample sample is taken taken in the form form of times times to failure failure (here (here time is taken to mean any appropriate measure of utilisation), • an analytical analytical techniq technique ue such as as Weibull which which is then then applied applied to the sample sample of failure data to derive a mathematical model for the behaviour of the sample, and hopefully of the population also, and finally  • some deductio deductions ns which which are are generated generated by by an examina examination tion of of the model. These deductions will influence the decisions to be made about the maintenance strategy  for the population. Themostdifficultpartofthisprocessistheacquisitionoftrustworthydata. Noamountofelegance in the statistical treatment of the data will enable sound judgements to be made from invalid data.  Weibull analysis requires times to failure. This is higher quality data than a knowledge of the number of failures in an interval. A failure must be a defined event and preferably preferably objective rather than some subjectively assessed degradation degradation in performance. A typical sample, therefore, might at its most superficial level comprise a collection of individual times to failure for the equipment under investigation. 2.1 2. 1 Qual Qu alit ity y of Da Data ta The quality of data is a most difficult feature to assess and yet its importance cannot be overstated. When there is a choice between a relatively relatively large amount of dubious dubious data and a relatively small amount amount of sound data, the latter is always preferred. preferred. The quality problem problem has several facets: • The data data should should be a statisti statistically cally rando random m sample sample of the the population. population. Exactl Exactly y what this means in terms of the hardware hardware will differ in each case. Clear Clearly ly the modification state of equipments may be relevant to the failures being experienced and failure data which cannot be allocated to one or other modification is likely to be misleading. mislead ing. By an examination examination of the sourc sourcee of the data the user must satisfy  himself that it contains no bias, or else recognise such a bias and confine the deductions accordingly. accordingly. For example, example, data obtained obtained from one user unit for an item experiencing failures of a nature which may be influenced by the quality of maintenance, local operating conditions/practices or any other idiosyncrasy of that unit may be used providing the conclusions drawn are suitably confined to the unit concerned. Warwick Manufacturing Group  Revision date: 6 December, 2004 20 04 2 THE USE OF WEIBULL IN DEFECT DATA ANALYSIS 2.2 • A less obvious data quality problem concerns the measure of utilisation to be used; it must not only be the appropriate one for the equipment as a whole, but it must also be appropriate for the major failure modes. As will be seen later, an analysis at equipment level can be totally misleading if there are several significant failure modes each exhibiting their own type of behaviour. The view of the problem at equipment level may give a misleading indication of the counter-strategies to be employed. The more meaningful deeper examination will not be possible unless the data contains mode information at the right depth and degree of integrity. • It is necessary to know any other details which may have a bearing on the failure sensitivity of the equipment; for example the installed position of the failures which comprise the sample. There are many factors which may render elements of a sample unrepresentative including such things as misuse or incorrect diagnosis. Quantity of Data  Whereas the effects of poor quality are insidious, the effects of inadequate quantity of data are more apparent and can, in part, be countered. To see how this may be done it is necessary to examine one of the statistical characteristics used in Weibull analysis. An equipment undergoing in-service failures will exhibit a cumulative distribution function (F(t)), which is the distribution in time of the cumulative failure pattern or cumulative percent failed as a function of time, as indicated by the sample. Consider a sample of 5 failures (sample size n = 5). The symbol i is used to indicate the failure number once the failure times are ranked in ascending order; so here i will take the integer values 1 to 5 inclusive. Suppose the 5 failure times are 2, 7, 13, 19 and 27 cycles. Now the first failure at2 cyclesmaybe thought tocorrespond toan F(t)valueof i/n,wherei = 1 and n = 5. ie F(t) @ 2 cycles = 1/5 or 0.2 or 20% Similarly for the second failure time of 7 cycles, the corresponding F(t) is 40% and so on. On this basis, this data is suggesting that the fifth failure at 27 cycles corresponds to a cumulative percent failed of 100%. In other words, on the basis of this sample, 100% of the population will fail by 27 cycles. Clearly this is unrealistic. A further sample of 10 items may contain one or more which exceed a 27 cycle life. A much larger sample of 1000 items may well indicate that rather than correspond to a 100% cumulative failure, 27 cycles corresponds to some lesser cumulative failure of any 85 or 90%. This problem of small sample bias is best overcome as follows: • Sample Size Less Than 50. A table of Median Ranks has ben calculated which gives a best estimate of the F(t) value corresponding to each failure time in the sample. This table is issued with these notes. It indicates that in the example just considered, the F(t) values corresponding to the 5 ascending failure times quoted are not 20%, 40%, 60%, 80% and 100%, but are 12.9%, 31.4%, 50%, 68.6% and 87.1%. It is this latter set of F(t) use values which should be plotted against the corresponding ranked failure times on a Weibull plot. Median rank values give the best estimate for the primary Weibull parameter and are best suited to some later work on confidence limits. Warwick Manufacturing Group  Revision date: 6 December, 2004 3 THE USE OF WEIBULL IN DEFECT DATA ANALYSIS • Sample Size Less Than 100. For sample sizes less than 100, in the absence of Median Rank tables the true median rank values can be adequately approximated using Bernard’s Approximation: F(t) = (i - 0.3)/(n + 0.4) • Sample Sizes Greater Than 100. Above a sample size of about 100 the problem of small sample bias is insignificant and the F(t) values may be calculated from the expression for the Mean Ranks: i/(n + 1) 3 THE MECHANICS OF WEIBULL ANALYSIS 3.1 The Value of Analysis On occasions, an analysis of the data reveals little that was not apparent from engineering judgement applied to the physics of the failures and an examination of the raw data. However, on other occasions, the true behaviour of equipments can be obscured when viewed by the most experienced assessor. It is alwaysnecessary to keepa balance betweendeductions drawn from data analysis and those which arise from an examination of the mechanics of failure. Ideally, these should be suggesting complementary rather than conflicting counter-strategies to unreliability. There aremany reliability characteristics of an itemwhich maybe of interest andsignificantly  more reliability measures or parameters which can be used to describe those characteristics.  Weibull will provide meaningful information on 2 such characteristics. First, it will give some measure of how failures are distributed with time. Second, it will indicate the hazard regime for the failures under consideration. The significance of these 2 measures of reliability is described later.  Weibull is a 3-parameter distribution which has the great strength of being sufficiently flexible to encompass almost all the failure distributions found in practice, and hence provide information on the 3 failure regimes normally encountered. Weibull analysis is primarily a graphical technique although it can be done analytically. The dangerin the analytical approach is that it takes away the picture and replaces it with apparent precision in terms of the evaluated parameters. However, this is generally considered to be a poor practice since it eliminates the judgement and experience of the plotter. Weibull plots are often used to provide a broad feel for the nature of the failures; this is why, to some extent, it is a nonsense to worry about errors ofabout1%whenusingBernard’sapproximation,whentheprocessofplottingthepointsand fitting the best straight line will probably involve significantly larger “errors”. However, the aim is to appreciate in broad terms how the equipment is behaving. Weibull can make such profound statements about an equipment’s behaviour that ±5% may be relatively trivial. Warwick Manufacturing Group  Revision date: 6 December, 2004 4 THE USE OF WEIBULL IN DEFECT DATA ANALYSIS 3.2 Evaluating the Weibull Parameters The first stage of Weibull analysis once the data has been obtained is the estimation of the 3  Weibull parameters:  : Shape parameter.  : Scale parameter or characteristic life.   : Location parameter or minimum life. The general expression for the Weibull F(t) is: t   F t 1 e   This can be transformed into: log log 1 1 F t  log t   log  It follows that if F(t) can be plotted against t (corresponding failure times) on paper which has a reciprocal double log scale on one axis and a log scale on the other, and that data forms a straight line, then the data can be modelled by Weibull and the parameters extracted from the plot. A piece of 2 cycle Weibull paper (Chartwell Graph Data Ref C6572) is shown at Annex A and this is simply a piece of graph paper constructed such that its vertical scale is a double log reciprocal and its horizontal scale is a conventional log. The mechanics of the plot are described progressively using the following example and the associated illustrations in plots 1 to 12 of Annex B. • Consider the following times to failure for a sample of 10 items: 410, 1050, 825, 300, 660, 900, 500, 1200, 750 and 600 hours. • Assemble the data in ascending order and tabulate it against the corresponding F(t) values for a sample size of 10, obtained from the Median Rank tables. The tabulation is shown at table 1 (Annex B). • Mark the appropriate time scale on the horizontal axis on a piece of Weibull paper (plot 2). • Plot on the Weibull paper the ranked hours at failure (t i) on the horizontal axis against the corresponding F(t) value on the vertical axis (plot 3). • If the points constitute a reasonable straight line then construct that line. Note that real data frequently snakes about the straight line due to scatter in the data; this is not a problem providing the snaking motion is clearly to either side of the line. When determining the position of the line give more weight to the later points rather than the early ones; this is necessary both because of the effects of cumulation and because the Weibull paper tends to give a disproportionate empha sis to the early points which should be countered where these are at variance with the subsequent points. Do not attempt to draw more than one straight line through the data and do not construct a straight line where there is manifestly a Warwick Manufacturing Group  Revision date: 6 December, 2004 5 THE USE OF WEIBULL IN DEFECT DATA ANALYSIS curve. In this example the fitting of the line presents no problem (plot 4). Note also that on the matter of how much data is required for a Weibull plot that any 4 or so of the pieces of data used here would give an adequate straight line. In such circumstances 4 points may well be enough. Generally, 7 or so points would be a reasonable minimum, depending on their shape once plotted. • The fact that the data produced a straight line when initially plotted enables 2 statements to be made: • The data can apparently be modelled by the Weibull distribution. • The location parameter or minimum life () is approximately zero. This parameter is discussed later. • The next step is to construct a perpendicular from the Estimation Point in the top left hand corner of the paper to the plotted line (plot 5). • Once the plotted line is obtained, information based on the sample can be extracted. For example, plot 6 illustrates that this data is indicating that a 400 hour life would result in about 15% of in-service failures for these equipments. Conversely, an acceptable level of in-service failure may be converted into a life; for example it can be seen from plot 6 that an acceptable level of in-service failure of say, 30% would correspond to a life of about 550 hours, and so on. • At plot 7 a scale for the estimate of the Shape Parameter   , is highlighted. This scale can be seen to range from 0.5 to 5, although    values outside this range are possible. • The estimated value of  , termed , is given by the intersection of the constructed perpendicular and the   scale. In this example,  is about 2.4 (plot 8).   • At plot 9 a dotted horizontal line is highlighted corresponding to an F(t) value of 63.2%. Now the scale parameter or characteristic life estimate  is the life which corresponds to a cumulative mortality of 63.2% of the population. Hence to determine  it is necessary only to follow the    Estimator line horizontally until it intersects the plotted line and then read off the corresponding time on the lower scale. Plot 10 shows that, based on this sample, these components have an  of about 830 hours. By this time 63.2% of them will have failed.    • At plot 11 the evaluation of the proportion failed corresponding to the mean of the distribution of the times to failure (P µ) is shown to be 52.5% using the point of intersection of the perpendicular and the P µ scale. This value is inserted in the F(t) scale and its intersection with the plotted line determines the estimated mean of the distribution of the times to failure ( ). In this case this is about 740 hours.  • One additional piece of information which can be easily extracted also is the median life; that is to say the life corresponding to 50% mortality. This is shown at plot 12 to be about 720 hours, based on this sample. Warwick Manufacturing Group  Revision date: 6 December, 2004 6 THE USE OF WEIBULL IN DEFECT DATA ANALYSIS 4 INTERPRETATION OF WEIBULL OUTPUT 4.1 Concept of Hazard Before examining the significance of the Weibull shape parameter    it is necessary to know something of the concept of hazard and the 3 so-called failure regimes. The parameter of interest here is the hazard rate, h(t). This is the conditional probability that an equipment will fail in a given interval of unit time given that it has survived until that interval of time. It is, therefore, the instantaneous failure rate and can in general be thought of as a measure of the probability of failure, where this probability varies with the time the item has been in service. The 3 failure regimes are defined in terms of hazard rate and not, as is a common misconception, in terms of failure rate. The 3 regimes are often thought of in the form of the so-called ‘bath-tub’ curve; this is a valid  concept for the behaviour of a system over its whole life but is a misleading model for the vast majority of components and, more importantly, their individual failure modes (see Reference 5 and 7). An individual mode is unlikely to exhibit more than one of the 3 characteristics of decreasing, constant or increasing hazard. Shape Parameter Less Than Unity.  A  value of less than unityindicates that the item or failure mode may be characterised by the first regime of decreasing hazard. This is sometimes termed the early failure of infant mortality period and it is a common fallacy that such failures are unavoidable. The distribution of times to failure will follow a hyper-exponential distribution in which the instantaneous probability of failure is decreasing with time in service. This hyper-exponential distribution models a concentration of failure times at each end of the time scale; many items fail early or else go on to a substantial life, whilst relatively few fail between the extremes. The extent to which  is below 1 is a measure of the severity of the early failures; 0.9 for example would be a relatively weak early failure effect, particularly if the sample size and therefore the confidence, was low. If there is a single or a predominant failure mode with a  , thenclearly component lifing is inappropriate since the replacement is more likely to fail than the replaced item. Just as importantly, a  gives a powerful indication of the causes of these failures, which are classically attributedto two deficiencies. First such failures result from poor qualitycontrol in the manufacturing process or some other mechanism which permits the installation of low quality components. It is for this reason that burn-in programmes are the common counterstrategy to poor quality control for electronic components which would otherwise generate an unacceptably high initial in-service level of failure. The second primary cause of infant mortality is an inadequate standard of maintenance activity, and here the analysis is pointing to a lack of qualityrather than quantity in the work undertaken. The circumstance classically associated with infant mortality problems is the introduction of a new equipment, possibly of new design, which is unfamiliar to its operators and its maintainers. Clearly in such situations, the high initial level of unreliability should decrease with the dissemination of experience and the replacement of weakling components with those of normal standard. The problem of infant mortalityhas been shown to be much more prevalent than might have been anticipated. In one particular study (Part 2 of Reference 6) it was found to be the dominant failure regime on a variety of mechanical components of traditional design. Warwick Manufacturing Group  Revision date: 6 December, 2004 7   THE USE OF WEIBULL IN DEFECT DATA ANALYSIS Shape Parameter Equal to Unity.  When the shape parameter has a value of approximately one, the Weibull analysis is indicating that constant hazard conditions apply. This is the special case where the degree of hazard is not changing with time in service and such terms as failure rate, MTBF and MTTF may be used meaningfully. This is the most frequently assumed distribution because to do so simplifies the mathematical manipulation significantly and opens up the possibility of using many  other reliability techniques which are based on, but rarely state, the precondition that constant hazard conditions apply. To assume constant hazard, with its associated negative exponential distribution of times to failure, over some or all of an equipment’s life must frequently  produce misleading conclusions. The term ‘random failures’ is often used to describe constant hazard and refers to the necessary conditions that failures be independent of each other and of time. Equipments which predominantly suffer constant hazard over their working lives should not be lifed since, by definition, the replacement has the same hazard or instantaneous probability of failure as the replaced item. Individual failure modes with  = 1 tend to be the exception. Frequently, an equipment will appear to exhibit constant hazard because it has several failure modes of a variety of types, none of which is dominant. This summation effect is a particular characteristic of complex maintained systems comprising multiple series elements whether they be electronic, electrical, mechanical or some combination, particularly when their lives have been randomized by  earlier failure replacements. The difficulty here is that the counter-strategy for the individual failure modes may well be significantly different to those suggested by constant hazard conditions for the system or equipment as a whole. There may well be, therefore, a need for a deeper analysis at mode level. Typical counter-strategies to known constant hazard conditions include de-rating, redundancy or modification. Shape Parameter Greater Than Unity. If the Weibull shape parameter is greater than one the analysis is indicating that increasing hazard conditions apply. The instantaneous probability of failure is therefore increasing with time; the higher the    value, the greater is the rate of increase. This is often called the ‘wear-out’ phase, although again this term can be misleading. The time dependence of failures now permits sensible consideration of planned replacement providing the total cost of a failure replacement is greater than the total cost of a planned replacement. The interval for such replacements should be optimised and there is at least one general technique (Reference 8) which will do this directly from theWeibull parameters, providingthe total costs areknown.  Various values of  can be associated with certain distributions of times to failure and the commonest causes of such distributions. A  value of about 2 arises from a times to failure distribution which is roughly log-normal - see Figure 1: Such distributions may be attributable to a wear-out phenomenon but are classically generated by situations where failure is due to the nucleation effect of imperfections or weaknesses, such as in crack propagation. A shape parameter of about 2 is an indication, therefore, of fatigue failure. As the  value increases above 2, the shape of the pdf approaches the symmetrical normal distribution until at    = 3.4 the pdf is fully normal (Figure 2).  A   value of this order indicates at least one dominant failure mode which is being caused by  wear or attrition. As the  value rises still further so does the rate of wear-out. Such situations need not necessarily be viewed with alarm; if the combined analysis for the 3 Weibull Warwick Manufacturing Group  Revision date: 6 December, 2004 8 THE USE OF WEIBULL IN DEFECT DATA ANALYSIS  pdf for  = 2 time Figure 1 Probability Density Function for a Shape Parameter of 2  pdf for  = 3.4 time Figure 2 Probability Density Function for a Shape Parameter of 3.4  pdf for  = 6 or 7 t0   time Figure 3 Probability Density Function for a Shape Parameter of 6 to 7 parameters indicates a pdf of the form shown below, of which a very high ,sayabout6or7,is just one element, then clearly a strategy to replace at t 0 might be highly satisfactory, particularly if it is a critical component, since the evidence suggests there will be no in-service failures once that life is introduced (Figure 3). Warwick Manufacturing Group  Revision date: 6 December, 2004 9 THE USE OF WEIBULL IN DEFECT DATA ANALYSIS The initiation of increasing hazard conditions and their rate of increase may be a function of the maintenance policy adopted and the operating conditions imposed on the equipment. Some General Comments on   The Weibull shape parameter provides a clear indication of which failure regime is the appropriate one for the mode under investigation and quantifies the degree of decreasing or increasing hazard. It can be used therefore, to indicate which counter-strategies are most likely to succeed and aids interpretation of the physics of failure. It can also be used to quantify the effects of anymodifications or maintenance policy changes. Although the use of median ranks provides the best estimate of  by un-biasingthe sample data, it is important to remember that the confidence which can be placed on the  estimate for any given failure mode is primarily a function of the sample size and quality of the data for that mode. 4.2 Scale Parameter or Characteristic LIfe  As stated earlier,  is the value in time by which 63.2% of all failures will have occurred. In this sense,  is just one point on the time scale, providing some standard measure of the distribution of times to failure. Looking back at the example of 10 items, it was found that  = 2.4 and  = 830 hours. This information helps the construction of a picture of the appropriate pdf.   To say here that the characteristic life is 830 hours is to say simply that roughly two thirds of all failures will occur by that time, according to this sample. As Sherwin showed in his study  at Reference 6, this is a very useful means of quantifying the effects of some change in maintenance strategy. There are, however, others some of which were evaluated in the example. The mean of this log-normalish distribution for these items was found to be about 740 hours and corresponded to a percent failed of 52.5%. Figure 5 can be sketched using these estimates:  Alternatively the median or 50% life was found to be about 720 hours: Here the 3 measures of time are all doing roughly the same thing. The characteristic life, however, is taken as the standard measure of position. Its significance is strengthened by the fact that when constant hazard conditions apply, ie  =1,thenthe  value becomes the mean f(t)  = 2.4 63.2%  = 830 time Figure 4 Probability Density Function and Characteristic Life Warwick Manufacturing Group  Revision date: 6 December, 2004 10 THE USE OF WEIBULL IN DEFECT DATA ANALYSIS f(t)  = 2.4 52.7% time = 740 Figure 5 Probability Density Function and Mean Life f(t)  = 2.4 50% life = 720 time Figure 6 Probability Density Function and Median Life time between failures (MTBF) for a repairable equipment or a mean time to failure (MTTF) for a non-repairable equipment, and is therefore the inverse of the constant hazard failure rate. This is the only circumstance in which    may be termed an MTBF/MTTF. 4.3 Location Parameter or Minimum Life It was briefly stated during the example that if a reasonable straight line could be fitted to the initial plot, then the value of the location parameter is approximately zero. Sometimes, however, the first plot may appear concave when viewed from the bottom right hand corner of the sheet (Figure 7):  When this occurs it is necessary to subtract some quantity of time ( ) from every failure time used to plot the curve. This is best done by a method attributed to General Motors and shown in Annex C. Using this or any other suitable method, an estimate of , termed , can be obtained. The estimate is enhanced by subtracting its value from every failure time and replotting the data: if  is too small the curve will remain concave but to a lesser degree than before: if  is too large the plot will become convex; and the best estimate of  isthatvaluewhichwhen subtracted from all the failure times gives the best straight line.     Warwick Manufacturing Group  Revision date: 6 December, 2004 11 THE USE OF WEIBULL IN DEFECT DATA ANALYSIS  x   x   x  F(t)  x   x   x   x  time Figure 7 Representing Points on a Curve using Weibull Paper The significance of    is that it is some value of time by which the complete distribution of times to failure is shifted, normally to the right, hence the term ‘location’. In the earlier example the distribution with  = 0 is shown at Figure 4. If, however,  had taken some positive value, say 425 hours, then this value must be added to all the times to failure extracted from the subsequent analysis of the straight line, and Figure 4 would have changed to that illustrated at Figure 8.   Here two thirds of the population do not fail until 1245 hours and most importantly the   value or minimum life value has shifted the time origin such that no failures are anticipated in the first 425 hours of service. The existence of a positive location parameter is therefore a highly desirable feature in any equipment and the initial plot should always be examined for a potential concave form.  A further example of a 3-parameter Weibull plot is given at Annex D. f(t)  = 2.4 63.2%  = 425 830 time new  = 830 + 425 = 1255 Figure 8 Effect of Location Parameter Warwick Manufacturing Group  Revision date: 6 December, 2004 12 THE USE OF WEIBULL IN DEFECT DATA ANALYSIS 5 PRACTICAL DIFFICULTIES WITH WEIBULL PLOTTING 5.1 Scatter The problem of scatter in the original data and the resultant snaking effect this can produce has been briefly mentioned. At Annex E, however, is a plot using 11 pieces of real data which illustrates a severe case of snaking. It is possible to plot a line and an attempt has been made in this case which gives the necessary added weight to laterpoints. The difficulty is obvious; it is necessary to satisfy yourself that you are seeing true snaking about a straight line caused by  scatter of the points about the line and not some other phenomenon. 5.2 Extrapolation Successful Weibull plotting relies on having historical failure data. Inaccuracies will arise if the span in time of that data is not significantly greaterthan the mean of the distribution of times to failure. If data obtained over an inadequate range is used as a basis for extrapolation (i.e.) extending the plotted line significantly, estimates of the 3 parameters are likely to be inaccurate and may well fail to reveal characteristics of later life such as a bi-modal wear-out phenomenon. The solution is comprehensive data at the right level. 5.3 Multi-Modal Failures The difficulty of multi-modal failures has been mentioned previously. In the same way that the distribution of times to failures for a single mode will be a characteristic of that mode, so the more modes there are contributing to the failure data, the more the individual characteristics of number of failure modes often tends to look like constant hazard (  = 1.0). In some cases this has been found to be so even when the modes themselves have all had a high wearout characteristic (  3 or 4). This tendency is strongest when there are many modes none of which is dominant. Hence a knowledge of the failure regimes of the individual failure modes of an equipment is more useful in formulating a maintenance policy than that of the failure regime of the equipment itself. The solution once again is data precise enough to identify the F(t) or  time Figure 9 Representation of Multi-Modal Behaviour on Weibull Paper Warwick Manufacturing Group  Revision date: 6 December, 2004 13 THE USE OF WEIBULL IN DEFECT DATA ANALYSIS characteristics of all the significant failure modes. A Weibull plot using data gathered at equipmentlevel mayor maynot indicate multi-modal behaviour. Themostfrequent manifestation of such behaviour is a convex or cranked plot as shown in Figure 9. The cranked plot shown above should not normally be drawn since it implies the existence of 2 failure regimes, one following the other in time. This is rarely the case; in general the bi- or multi-modal plots will be found to be mixed along both lines, because the distributions of times to failure themselves overlap. This is illustrated in Figure 10. mode 1 —  < 1, hence infant mortality f(t) mode 2 —  > 1, showing time dependent failures time Figure 10 Multiple Probability Density Functions One example of this bi-modal behaviour is quoted in Reference 6. There a vacuum pump was found to have one mode of severe infant mortality ( = 0.42) combined with another of wearout( = 3.2). It is most unlikely that an analysis of theircombined times to failure would have suggested an adequate maintenance strategy for the item as a whole. The convex curve also shown in Figure 9 indicates the presence of corrupt or multi-modal data. One form of corruption stems from the concept of a negative location parameter; if life is consumed in storage but the failure data under analysis is using an in-service life measured once the items are issued fromstore,thenclearlythedataiscorruptinthatonlyapartlifeisbeingusedintheanalysis. Once adequate multi-modal data has been obtained it is possible to separate the data for each mode and replot all the data in such a way as to make maximum use of every piece of life information. This approach provides more confidencethan simply plotting failure data for the individual mode and is best done using an adaptation of the technique for dealing with multiply-censored data; this topic is covered later. 5.4 Confidence Limits  As was pointed out earlier, most forms of analysis will give a false impression of accuracy and  Weibull is no exception, particularly when the same size is less than 50. The limitations of the data are best recognised by the construction of suitable confidence limits on the original plot. The confidence limits normally employed are the 95% lower confidence limit (LCL) or 5% Ranks, and the 5% upper confidence limit (UCL) or 95% Ranks, although other levels of confidencecanbeused. WiththesenotesaretablesofLCLandUCL rankswhichcanbeseentobea function solely of sample size. The technique for using these ranks consists of entering the Warwick Manufacturing Group  Revision date: 6 December, 2004 14 THE USE OF WEIBULL IN DEFECT DATA ANALYSIS vertical axis of the Weibull plot at the i th F(t) value quoted in the tables for the appropriate samplesize. A straight horizontal lineshould be drawn from the point of entry to intersect the line constructed from the data. From the point of intersection, move vertically up (for a lower limit) or down (for an upper limit) until horizontal with the corresponding i th plotted point. The technique is shown at Plot 1 of Annex F for the lower bound using the same example as in  Annex B. The first value obtained from the table for a sample size of 10 is 0.5; this cannot be usedsinceitdoesnotintersecttheplottedline. Thenextvalueis3.6andthisisshowninPlot1 togeneratepoint(1)onthelowerbound. Thethirdpointofentryisat8.7andthisisshownto produce point(2) which is level with the third plottedpoint for the straight line,and so on. The primary use of this lower bound curve constructed through the final set of points is that it is a visual statement of how bad this equipment might be and still give rise to the raw data observed, with 95% confidence. Hence it can be said here that although the best estimate for  is 830 hours, we can be only 95% confident, based on the data used, that the true    is greater than or equal to 615 hours. Similarly at Plot 2, which shows the construction of a 95% upper bound, we can be 95% confident that the true    is less than or equal to 1040 hours. These 2 statements can be combined to give symmetrical 90% confidence limits of between 615 and 1040 hours. This range can only be reduced by either diminishing the confidence level (and therefore increasing the risks of erroneous deduction) or by increasing the quantity of data.  5.5 Censoring of Sample Data Often samples contain information on incomplete times to failure in addition to the more obviously useful consumed lives at failure. This incomplete data may arise because an item has to be withdrawn for some reason other than the failure which is beingstudied. If the equipment suffers multi-modal failures then in an analysis of a particular mode, failure times attributable to all other modes become censorings. Alternatively the data collection period may end without some equipments failing, ie unknown finish times. The outcome of suchsituations is generally a series of complete failure times and a series of incomplete failure times or censorings for the mode under investigation. This latter information, this collection of times when the equipment did not fail for the particular reason cannot be ignored since to do so would bias the analysis, and diminish the confidence level associated with subsequent statements drawn from the plot. The assumption is generally made that the non-failures would have failed with equal probability at any time between the known failures or censored lives or after all of them. Thereforean itemremoved during inspection because it is nearing unacceptablelimits is closer to a failure and is not a censoring. The mechanics of dealing with censored data require the determination of a mean order number for each failure; this may be considered as an alternative to the failure number i used previously, the primary difference being that the mean order number becomes a non-integer once the first censoring is reached. The technique is outlined using the example at Annex G.  As a first step a table is constructed with columns a and b listing in ascending order the failure and censoring times respectively. Column (c) is calculated as the survivors prior to each event in either of columns a or b; where the event is a censoring the correspondingsurvivingnumber is shown in parenthesis by convention. Clearly the data in the sample is multiply-censored in that it is a mixture of failure and censored times; a total of 7 failures and 9 censorings gives a sample size n of 16. Warwick Manufacturing Group  Revision date: 6 December, 2004 15 THE USE OF WEIBULL IN DEFECT DATA ANALYSIS Column (d) is obtained using the formula: mi  Where m i mi n 1 mi 1 1 1 ki = current mean order number mi-1 = previous mean order number n = total sample size for failure and censorings ki = number of survivors prior to the failure or censoring under consideration Mean order number values are determined only for failures. Once the first censoring occurs at 65, all subsequent mi values are non-integers. The median rank values at column (e) are taken from the median rank tables using linear interpolation when necessary. For purposes of comparison only, the equivalent median ranks obtained from Bernard’s Approximation, (i-0.3)/(n + 0.4) are included at column (f). These are obtained by substituting m i for i in the standard expression. These can be seen to be largely in agreement with the purer figures in column (e). Finally 5% LCL AND 95% UCL figures are included at columns (g) and (h). These are obtained from the tables using linear interpolation where necessary. The median rank figures in column (e) are plotted on Weibull paper against the corresponding failure times at column a in the normal way. The plot is illustrated at Plot 1 of Annex G, and produces ,  and  estimates without difficulty. For completeness, Plot 2 shows the 5% LCL  AND 95% UCL curves; a 90% confidence range for  of between 90 and 148 units of time is obtained.  6 COMPARISON WITH HAZARD PLOTTING It is often thought that Weibull plots are no better than plotting techniques based on the cumulative hazardfunction calculated from sample data. Such methods will give estimates of the 3 Weibull parameters and the mechanics of obtaining them are often slightly simpler than for the equivalent application of Weibull. However, cumulative hazard plots give little feel for the behaviour of the equipmentin terms of the levels of risk of in-service failures for a proposed life. More importantly, such methods contain no correction for small sample bias and are therefore less suitable for use with samples smaller than 50. This limitation is is compounded by the difficulty of attempting the evaluation of confidence limits on a cumulative hazard plot. Finally, cases have occurred where cumulative hazard plots have failed to indicate multimodal behaviour which was readily apparent from a conventional Weibull plot from the same data. Warwick Manufacturing Group  Revision date: 6 December, 2004 16 THE USE OF WEIBULL IN DEFECT DATA ANALYSIS 7 CONCLUSIONS The ability of the Weibull distribution to model failure situations of many types, including those where non-constant hazard conditions apply, make it one of the most generally useful distributions for analyzing failure data. The information it provides, both in terms of the modelled distribution of times to failure and the prevailing failure regime is fundamental to the selection of a successful maintenance strategy, whether or not component lifing is an element in that strategy.  Weibull’s use of median ranks helps overcome the problems inherent in small samples. The degree of risk associated with small samples can be quantified using confidence limits and this can be done for complete or multiply-censored data. Weibull plots can quantify the risks associated with a proposed lifing policy and can indicate the likely distribution of failure arisings. In addition, they may well indicate the presence of more than one failure mode. However,  Weibull is not an autonomous process for providing instant solutions; it must be used in conjunction with a knowledge of the mechanics of the failures under study. The final point to be made is that Weibull, like all such techniques, relies upon data of adequate quantity and quality; this is particularly true of multi-modal failure patterns. REFERENCES 1. 2. 3. 4. 5. 6. 7. 8. Weibull W.  A statistical distribution function of wide application . ASME paper 51-A-6, Nov 1951. Mann R N, Schafer R E and Singpurwalla N D.  Methods for statistical analysis of reli ability and life data. Wiley 1974. Bompas-Smith J H.  Mechanical survival - the use of reliability data.  McGraw-Hill 1973. Carter A D S.  Mechanical reliability. Macmillan 1972. British Standard 5760: Part 2: 1981. Reliability of systems, equipments and components;  guide to the assessment of reliability. Sherwin D J and Lees F P.  An investigation of the application of failure data analysis to  decision making in the maintenance of process plant. Proc Instn Mech Engrs, Vol 194, No 29, 1980. Carter ADS.  The bathtub curve for mechanical components - fact or fiction.  Conference on Improvement of Reliability in Engineering, Instn Mech Engrs, Loughborough 1973. Glasser G J. Planned replacement: some theory and its application. Journal of Quality  Technology, Vol 1,No 2. April 1969. Warwick Manufacturing Group  Revision date: 6 December, 2004 17   THE USE OF WEIBULL IN DEFECT DATA ANALYSIS  ANNEX A TWO CYCLE WEIBULL PAPER Warwick Manufacturing Group  Revision date: 6 December, 2004 18 THE USE OF WEIBULL IN DEFECT DATA ANALYSIS Warwick Manufacturing Group  Revision date: 6 December, 2004 19 THE USE OF WEIBULL IN DEFECT DATA ANALYSIS  ANNEX B PROGRESSIVE EXAMPLE OF WEIBULL PLOTTING  Arranging the Raw Data Failure Number (i) Ranked Hours at Failure (ti) Median Rank Cumulative % Failed F(t) 1 300 6.7 2 410 16.2 3 500 25.9 4 600 35.5 5 660 45.2 6 750 54.8 7 825 64.5 8 900 74.1 9 1050 83.8 10 1200 93.3 The following plots illustrate Weibull plotting. Warwick Manufacturing Group  Revision date: 6 December, 2004 20 THE USE OF WEIBULL IN DEFECT DATA ANALYSIS Warwick Manufacturing Group  Revision date: 6 December, 2004 21 THE USE OF WEIBULL IN DEFECT DATA ANALYSIS Warwick Manufacturing Group  Revision date: 6 December, 2004 22 THE USE OF WEIBULL IN DEFECT DATA ANALYSIS Warwick Manufacturing Group  Revision date: 6 December, 2004 23 THE USE OF WEIBULL IN DEFECT DATA ANALYSIS Warwick Manufacturing Group  Revision date: 6 December, 2004 24 THE USE OF WEIBULL IN DEFECT DATA ANALYSIS Warwick Manufacturing Group  Revision date: 6 December, 2004 25 THE USE OF WEIBULL IN DEFECT DATA ANALYSIS Warwick Manufacturing Group  Revision date: 6 December, 2004 26 THE USE OF WEIBULL IN DEFECT DATA ANALYSIS Warwick Manufacturing Group  Revision date: 6 December, 2004 27   THE USE OF WEIBULL IN DEFECT DATA ANALYSIS Warwick Manufacturing Group  Revision date: 6 December, 2004 28 THE USE OF WEIBULL IN DEFECT DATA ANALYSIS Warwick Manufacturing Group  Revision date: 6 December, 2004 29 THE USE OF WEIBULL IN DEFECT DATA ANALYSIS Warwick Manufacturing Group  Revision date: 6 December, 2004 30 THE USE OF WEIBULL IN DEFECT DATA ANALYSIS  ANNEX C ESTIMATION OF WEIBULL LOCATION PARAMETER Steps: 1. 2. 3. 4. 5. Plot the data initially, observing a concave curve when viewed from the bottom right hand corner. Select 2 extreme points on the vertical scale (say a and b), and determine the corresponding failure times (t1  and t3). Divide the physical distance between points a and b in half without regard for the scale of the vertical axis, and so obtain point c. Determine the failure time corresponding to point c (ie t2). he estimate of the location parameter is given by:   t2 t3 t3 t2 t2 t2 t2 t1 t1 Weibull Plot  b    = t2 - (t3 - t2)(t2 - t1) (t3 - t2) - (t2 - t1) a t1 t2 t3 time Figure 11 Estimation of Location Parameter Warwick Manufacturing Group  Revision date: 6 December, 2004 31 THE USE OF WEIBULL IN DEFECT DATA ANALYSIS  ANNEX D EXAMPLE OF A 3-PARAMETER WEIBULL PLOT Problem: to determine the Weibull parameters for the following (ordered) sample times to failure: 1000, 1300, 1550, 1850, 2100, 2450 and 3000 hours. Steps: 1. 2. 3. 4. 5. 6. Plot initially (Plot 1). Having identified a concave form apply the technique at Annex C (Plot 2). Determine   and evaluate modified times to failure. Plot modified points and confirm a straight line (Plot 3). Extract    and    in the normal way remembering to add    to the straight line value for  (Plot 4). Sketch the probability density function (Plot 5). Plotting the raw data: Failure Number (i) Ranked Hours at Failure (ti) Median Rank Cumulative % Failed F(t) 1 1000 9.4 2 1300 22.8 3 1550 36.4 4 1850 50.0 5 2100 63.6 6 2450 77.2 7 3000 90.6 Warwick Manufacturing Group  Revision date: 6 December, 2004     32 THE USE OF WEIBULL IN DEFECT DATA ANALYSIS Warwick Manufacturing Group  Revision date: 6 December, 2004 33 THE USE OF WEIBULL IN DEFECT DATA ANALYSIS Warwick Manufacturing Group  Revision date: 6 December, 2004 34 THE USE OF WEIBULL IN DEFECT DATA ANALYSIS From Plot 2: t1  = 810 hours t2   = 1500 hours t3   = 4000 hours General expression from Annex D: t3  t2  1500   t3 t2 t2 t2 t1 t2 t1 4000 1500 1500 810 4000 1500 1500 810 1500 953 547 hours Replot using: 1000 - 547 = 453 1300 - 547 = 753 1550 - 547 = 1003 1850 - 547 = 1303 2100 - 547 = 1553 2450 - 547 = 1903 3000 - 547 = 2453 f(t)  b = 1.9 63.2%  = 547   1560 time  = 547 + 1560 = 2107 Figure 12 Probability Density Function Warwick Manufacturing Group  Revision date: 6 December, 2004 35 THE USE OF WEIBULL IN DEFECT DATA ANALYSIS Warwick Manufacturing Group  Revision date: 6 December, 2004 36 THE USE OF WEIBULL IN DEFECT DATA ANALYSIS  ANNEX E THE EFFECT OF SCATTER Warwick Manufacturing Group  Revision date: 6 December, 2004 37   THE USE OF WEIBULL IN DEFECT DATA ANALYSIS Warwick Manufacturing Group  Revision date: 6 December, 2004 38 THE USE OF WEIBULL IN DEFECT DATA ANALYSIS  ANNEX F 95% CONFIDENCE LIMITS FOR WEIBULL Warwick Manufacturing Group  Revision date: 6 December, 2004 39 THE USE OF WEIBULL IN DEFECT DATA ANALYSIS Warwick Manufacturing Group  Revision date: 6 December, 2004 40 THE USE OF WEIBULL IN DEFECT DATA ANALYSIS Warwick Manufacturing Group  Revision date: 6 December, 2004 41 THE USE OF WEIBULL IN DEFECT DATA ANALYSIS  ANNEX G WEIBULL PLOT OF MULTIPLY-CENSORED DATA Warwick Manufacturing Group  Revision date: 6 December, 2004 42 THE USE OF WEIBULL IN DEFECT DATA ANALYSIS    r    e    p    p     U    d     )     k    n    u     h     7     6     4    n    a    o     (     1     2     3     R    B     %     5     9     8     4  .   —     2     4     2     1  .     9     4   —     8     1  .     4     6     5     4  .   —     0     8   —    r    e    w    o    d     L     )     k    n  .     2  .     3  .    g     3    u     (    n     0     2     5    o    a    B     R     %     5     2  .   —     3     9     8  .     3     1   —     5     6  .     5     2     4     1  .   —     3     4   —    x    o    r    p    p     6     A     )     7     7     3  .     4  .    s    %    f(     2  .     0     d     4     1     6    r     1    a    n    r    e     B     5     0  .   —     3     2     3     6  .     9     2   —     9     0  .     4     4     5     3  .   —     3     6   —     %    s     k    n    a  .     3  .     R     )  .     2    e     2     0     (     4     1     6     1    n    a     i     d    e     M     9     8  .   —     2     2     i     M    r    e     b    m    u     N     )     d     1     2     3    r    e     (     d    r     O    n    a    e     M     8     0  .     4     9     4  .     9     2   —     3     0  .     4     4     1     3  .   —     3     6   —   —     3     5  .     7     9     6  .   —     0     1   —     6     1  .     5     8     0  .     4     3     1     1   —     1     2     1     1     1     1     6     6     1     1     8     3     0  .     4    a    t    a     D     d    e    r    o    s    n    e     C    y     l    p     i    t     l    u     M     i     k    s    r    o    v     i    v    r    u     S     )     5     4     )    c     6     1     1     1     3     (     1    s    e    m     i     T    g     i     )    n   c     b     i    r     (    o    s    n    e     C     i    t    s    e    m     i     7  .     2  .     5  .     T     )    a     1     9     7     (    e     3     3     5    r    u     l     i    a     F     2     1     1     1     )     )     )     )     )     )     )     0     )     9     8     7     6     5     4     3     1     (     2     1     (     (     (     (     (     (     (     0  .  .     0  .     5  .     3  .     2  .     7     1     5     5     7     8     4     0     7     7     8     8     8     1     0  .     5     6     8  .     5     6 Warwick Manufacturing Group  Revision date: 6 December, 2004     0  .     0     7     2  .     9     0     1     8  .     5     0     1     0  .     0     3     1     0  .     0     1     1 43 THE USE OF WEIBULL IN DEFECT DATA ANALYSIS Warwick Manufacturing Group  Revision date: 6 December, 2004 44