Adressable Intelligent Fire Alarm Panel Manual

ADDRESSABLE INTELLIGENT FIRE ALARM SYSTEM USER MANUAL NAVEEN ALARM SYSTEMS INDIA PVT LTD Office: 1/10 Abilasha apartments, Gopalakrishna Street T.Nagar Chennai - 17. INDIA PH: +91 44 23457110 / 28157868 email: [email protected] URL: www.naveenalarm.com Works: No.9 Lakshmi Vinayagar Koil Street Ambal nagar, Ekadduthangal Chennai - 97. INDIA Ph: +91 44 32557282/23457111 1 TABLE OF CONTENTS INTRODUCTION: ......................................................................................

   EMBED


Share

Transcript

  1  ADDRESSABLEINTELLIGENTFIRE ALARM SYSTEM USERMANUAL NAVEEN ALARM SYSTEMS INDIA PVT LTD Office: 1/10 Abilasha apartments, Gopalakrishna StreetT.NagarChennai - 17. INDIA PH: +91 44 23457110 / 28157868email: [email protected]: www.naveenalarm.com   Works: No.9 Lakshmi Vinayagar Koil Street Ambal nagar, EkadduthangalChennai - 97. INDIA Ph: +91 44 32557282/23457111  2 TABLE OF CONTENTS INTRODUCTION:.......................................................................................................................................................................31.0 SYSTEM OVERVIEW:............................................................................................................................................................41.1 Description:.............................................................................................................................................................51.2 Features:.................................................................................................................................................................51.3 Technical Specifications:........................................................................................................................................62.0 FRONT PANEL CONTROLS AND INDICATION:......................................................................................................................62.1 Control Keys:...........................................................................................................................................................72.2 Front Panel LED Indication:......................................................................................................................................73.0 INSTALLATION:....................................................................................................................................................................84.0 BASIC SYSTEM MODULE:.....................................................................................................................................................84.1 Power:.....................................................................................................................................................................94.1.1 DC Input:...........................................................................................................................................94.1.2 Battery Connections:.........................................................................................................................94.1.3 Loop Connections:.........................................................................................................................104.1.4 Conventional Sounder Connections:..............................................................................................104.1.5 Auxiliary Power Output Connections:...............................................................................................104.1.6 Relay Connections:.........................................................................................................................105.0 CONFIGURING THE PANEL:...............................................................................................................................................106.0 PROGRAMMING/OPERATING:..........................................................................................................................................196.1 Level 1 Access Mode:...........................................................................................................................................196.2 Level 2 Access Mode:...........................................................................................................................................206.2.1 Set time & date:..............................................................................................................................216.2.2 Enter zone area:..............................................................................................................................226.2.3 Enter device point:..........................................................................................................................226.2.4 Zone config report:.........................................................................................................................226.2.5 Erase data log report:.....................................................................................................................236.2.6 Change password:.........................................................................................................................236.2.7 Zone isolation:.................................................................................................................................246.2.8 Assign devices:................................................................................................................................246.2.9 Add / remove device manually:.....................................................................................................256.3 Level 3 access mode (engineering mode):.........................................................................................................256.3.1 Set serial no:....................................................................................................................................266.3.2 Set default value:............................................................................................................................266.3.3 Write bus data:................................................................................................................................267.0 TROUBLE SHOOTING:........................................................................................................................................................288.0 MAINTENANCE:................................................................................................................................................................299.0 WARNING AND CAUTION:................................................................................................................................................2910.0 BLOCK DIAGRAM AND CIRCUIT CONNECTIONS OF ADDRESSABLE PANEL:......................................................................31  3 INTRODUCTION:    Airlight addressable intelligent Fire Alarm System is a state-of-the-art system providing early warningof a fire so that people can be evacuated and action can be taken to stop the fire at the earliest.The system can be integrated with AHU, AC supply, Access control, Fire Fighting system, BMS and so on.  Intelligent Addressable Automatic Fire Detection and Alarm system consists of the following:1.    Addressable Single Loop Fire Alarm panel2.    Addressable photoelectric smoke detector3.    Addressable heat detector4.    Addressable Multisensor5.    Addressable Manual Call Point6.    Addressable Sounder beacon7.   Control Module8.   Isolator Module Fire Alarm Panel  works on 230 Volt AC with backup supply of 24 Volt DC battery. Power supply is fed to otherdevices from the Fire Alarm panel through a two core cable  which is also used for sending Fire signal fromDetector to Panel and also from Panel to Sounder employing power-line communication technique. ThePanel also sends fire alert signal to PC. Monitor screen pops up all the indications as shown in the fire alarm panel along with mimic layout, fire affected zone, etc. Photoelectric smoke detector  senses smoke and sends advance signals to the Fire Alarm Panel giving its ID.   Heat detector  is a device that responds to changes in ambient temperature and sends advance signals tothe Fire Alarm Panel giving its ID . Multisensor  is a combination of smoke & heat detector that senses heat / smoke andsends advance signals to the Fire Alarm Panel giving its ID.   Manual Call Point provides additional facility to send fire signal to Fire Alarm panel by  manually activating the signal from the fire affected zone.   Sounder Beacon activates audio visual alarm on receipt of fire warning signal from Fire Alarm panel. Thisalerts everyone to arrange evacuation and fire fighting.    4 Control Module provides “potential free” contact for activating user designed external alarms. Isolator module provides short circuit protection and isolates the devices beyond the short circuit pointand allows normal communication up to the point where the short circuit occurred.   1.0 SYSTEM OVERVIEW: The fire alarm panel, housed in a powder coated metal cabinet, consists of SMPS, Keypad and CPU card.  The front panel is protected by a lid with a cam lock  and also it houses a 2x40 LCD display, Navigationkeys, Alpha numeric keypad, and Zonal Fire LED indicators.  The panel provides power to other devices connected through two core cable. Fire alert signals areexchanged through the same cable. Fire alarm panel, through a two core cable, receives fire alarms from detectors and manual call points.On receipt of signal from Detectors/MCP along with ID, the panel sends out alarm signal to corresponding Sounder beacon for raising audio visual alarm to alert the people for evacuation. ThePanel also sends out fire alert signal to PC. Monitor screen pops up all the indications as shown in theFire Alarm Panel along with mimic layout, fire affected zone, etc.