Preview only show first 10 pages with watermark. For full document please download

Drawings

Page 1 of 57 Effective from Feb, 2010 Master List No. TIM 0003 Revision 7 RESEARCH DESIGNS AND STANDARDS ORGANISATION TRACTION INSTALLATION DIRECTORATE 1.0 TITLE : MASTER LIST OF DRAWINGS OF EQUIPMENTS AND MATERIALS FOR TRACTION INSTALLATION . PREPARED BY APPROVED BY SE/DOC. DTI-P&S Page 2 of 57 Sl. N NO. o. Effective from Feb, 2010 DRAWING R E V Master List No. TIM 0003 Revision 7 DATE DESCRIPTION OF ISSUE S I Z E INDEX Sl No DESCRIPTION PAGE NO. CHAPTER - I - OVERHEAD EQUIPMENT 1

   EMBED


Share

Transcript

  Page 1 of 57 Effective from Feb, 2010 Master List No. TIM 0003 Revision 7  RESEARCH DESIGNS AND STANDARDS ORGANISATION TRACTION INSTALLATION DIRECTORATE   1.0 TITLE : MASTER LIST OF DRAWINGS OF EQUIPMENTSAND MATERIALS FOR TRACTION INSTALLATION .PREPARED BY SE/DOC.APPROVED BY DTI-P&S    Page 2 of 57 Effective from Feb, 2010 Master List No. TIM 0003 Revision 7 SIZESl.No.DRAWINGNO.REVDESCRIPTIONDATEOFISSUE I N D E X SlNoDESCRIPTION PAGE NO. CHAPTER - I - OVERHEAD EQUIPMENT  1 GENERAL ARRANGEMENT FOR CONVENTIONAL OHE 032 ATD series 093 COMPONENTS , FITTINGS, EQUIPMENTS AND SMALL PART STEEL WORKS 104 GENERAL ARRANGEMENT AND FITTINGS FOR COMPOSITE OHE(ALUMINIUM ALLOY CATENARY AND COPPER CONTACT WIRE)21 CHAPTER - II - POWER SUPPLY INSTALLATION  1 GENERAL ARRANGEMENT OF SUB STATION LAYOUT ,SWITCHINGSTATION, BT, REMOTE CONTROL AND EARTHING ARRANGEMENT.   232 GENERAL ARRANGEMENT OF SUB STATION LAYOUT ,SWITCHINGSTATION, BT, REMOTE CONTROL AND EARTHING ARRANGEMENT FOR 2X 25 kV ‘AT’ SYSTEM.283 SHUNT CAPACITORS AND PROTECTION FOR 25 kV ac TRACTION SYSTEM 294 PROTECTION FOR 2 X 25 kV ac ‘AT’ SYSTEM 305 COMPONENTS AND FITTINGS 316 HIGHER CAPACITY CONNECTORS FOR 220 kV AND 25 kV (50 mm O/DALUMINIUM BUS BAR) SYSTEM33 CHAPTER - III - CIVIL   1 OHE MAST (STEEL)   352 OHE PORTALS, TTC, DROPARMS AND SPS   363 STRUCTURAL LAYOUT, STRUCTURES AND FOUNDATION FOR TRACTIONSUB STATION394 STRUCTURES, FENCING AND SPS FOR SWS AND BT 415 OHE SUPERMAST AND SPS 436 EMPLOYMENT SCHEDULE OF OHE MAST 457 OHE FOUNDATIONS 538 MISCELLANEOUS 549 SPUN PRESTRESS CEMENT CONCRETE (PSC) OHE MAST 54  Page 3 of 57 Effective from Feb, 2010 Master List No. TIM 0003 Revision 7 SSl.No.DRAWING NO. REVDESCRIPTION DATEOFISSUEIZE Chapter - I - OVERHEAD EQUIPMENT 1.   GENERAL ARRANGEMENT FOR CONVENTIONAL OHE A1   ETI/OHE/G/00111 Sh.1 C Extra allowance for setting of structures on curves(broad gauge)20.10.05 22   RE/33/G/00111 Sh.2 - Extra allowance for setting of structures on curves(metre gauge)17.05.62 33   ETI/OHE/G/00112 D Standard setting of structures in the vicinity of signals(broad gauge)20.10.05 14   ETI/OHE/G/00131 - Typical design of side bearing foundation 21.08.71 25   ETI/OHE/G/00144 Sh.3 C Standard drilling schedule of OHE mast 9.5 m long(RSJ and BFB)24.12.97 26   ETI/OHE/G/00158 Sh-1 - Employment schedule of bracket tubes regulatedconventional OHE (Cd Cu catenary and Cu contactwire 1000 kgf. tension each for wind pressure 75kgf  /.m228.06.84 27   ETI/OHE/G/00158 Sh-2 - Employment schedule of bracket tubes regulatedconventional OHE (Cd Cu catenary and Cu contactwire 1000 kgf tension each) for wind pressure112.5kgf /sq.m.28.06.84 28   ETI/OHE/G/00158 Sh- 3 - Employment schedule of bracket tubes regulatedconventional OHE (Cd Cu catenary and cu contactwire 1000 kgf tension each) for wind pressure 150 kgf  / sq.m.28.06.84 29   ETI/OHE/G/00159 Sh-1 - Employment schedule of bracket tubes unregulatedconventional OHE (Cd Cu catenary and Cu contactwire 1000 kgf tension each for wind pressure 75kgf  /sq.m.28.06.84 210   ETI/OHE/G/00159 Sh-2 - Employment schedule of bracket tubes unregulatedconventional OHE (Cd Cu catenary and Cu contactwire 1000 kgf tension each) for wind pressure112.5kgf /sq.m.28.06.84 211   ETI/OHE/G/00159 Sh- 3 - Employment schedule of bracket tubes unregulatedconventional OHE (Cd Cu catenary and Cu contactwire 1000 kgf tension each) for wind pressure 150 kgf  /sq.m.28.06.84 212   ETI/OHE/G/00161 - General distribution of droppers. 28.04.72 313   ETI/OHE/G/00166 A Dropper schedule for unregulated OHE with equalencumbrance (1.40/1.40).02.08.74 214   ETI/OHE/G/00167 A Dropper schedule for unregulated OHE with unequalencumbrance (1.40/0.90).02.08.74 215   ETI/OHE/G/00168 A Dropper schedule for unregulated OHE with unequalencumbrance (1.40/0.75).02.08.74 216   ETI/OHE/G/00169 A Dropper schedule for uninsulated overlap span. 01.12.94 217   ETI/OHE/G/00170 A Dropper schedule for insulated overlap span. 02.08.74 218   ETI/OHE/G/00173 B Dropper schedule for compensated OHE with equalencumbrance (1.40/1.40) for speed upto 160km/h.02.08.74 1  Page 4 of 57 Effective from Feb, 2010 Master List No. TIM 0003 Revision 7 SIZESl.No.DRAWINGNO.REVDESCRIPTIONDATEOFISSUEA19   ETI/OHE/G/00173-1 - Dropper schedule for regulated OHE in worn outcondition of 107 sqmm contact wire (9.75mm thickness)09.10.95 120   ETI/OHE/G/00174 B Dropper schedule for compensated OHE with unequalencumbrance (1.40/0.90) for speed upto 160km/h03.04.80 221   ETI/OHE/G/00175 A Dropper schedule for compensated OHE with unequalencumbrance (1.40/0.75) for speed upto 160km/h02.08.74 222   ETI/OHE/G/00176 D Dropper schedule for compensated OHE with unequalencumbrance (1.75/1.40) for speed upto 160km/h02.08.74 223   ETI/OHE/G/00177 A Dropper schedule for conventional regulated OHE withzero presage (1400/1400)05.09.94 224   RE/33/G/00181 A Outline of pantograph (BG & MG) 05.03.62 325   RE/33/G/00182 C Arrangement of pantograph multiple headed train BG 04.08.66 226   RE/33/G/00183 Sh. 1 B General clearance diagram on BG tracks (tangent and flatcurves )09.08.67 227   RE/33/G/00183 Sh. 2 - General clearance diagram on MG tracks (tangent andflat curves )06.06.62 228   RE/33/G/00184 Sh. 1 A General clearance diagram on BG tracks (sharp curves ) 10.04.62 329   RE/33/G/00184 Sh. 2 - General clearance diagram on MG tracks (sharp curves ) 06.06.62 230   RE/33/G/00185 Sh. 1 A Restricted clearance diagram on tangent tracks BG 16.04.64 231   RE/33/G/00185 Sh. 2 - Restricted clearance diagram on MG tracks (tangent andflat curves)06.06.62 232   ETI/OHE/G/00186 Sh.1- Restricted clearance diagram on curved track on BG 14.01.83 233   RE/33/G/00186 Sh. 2 - Restricted clearance diagram on MG tracks (sharpcurves)06.06.82 234   ETI/OHE/G/00187 A Chart showing the blow off, push up and oscillations of the standard a.c. OHE25.08.76 235   RE/33/G/00193 - Adjustment chart of regulating equipment winch type &pulley block type27.01.67 136   ETI/OHE/G/00195 A Adjustment chart of regulating equipment three pulleytype 3:1 ratio28.06.94 237   RE/33/G/00197 A Cantilever adjustment chart at mean temperature 35 0 C 31.01.61 138   ETI/OHE/G/00202 - Span and stagger chart (conventional OHE Cd coppercatenary and Cu contact wire) for wind pressure 75,112.5& 150 kgf/sq. m27.03.85 139   ETI/OHE/G/00222Sh. 1- Sag and tension chart for loaded catenary 11.09.72 140   RE/33/G/01101 Sh. 1 A General formation of single track in embankments andcuttings BG07.09.62 341   RE/33/G/01101 Sh. 2 - General formation of single track in embankments andcuttings MG06.04.62 342   RE/33/G/01102 Sh. 1 A General formation of double track in embankments andcuttings BG07.04.62 243   RE/33/G/01102 Sh. 2 - General formation of double track in embankments andcuttings MG06.04.62 244   RE/33/G/01103 Sh. 1 A General formation of multiple tracks BG 07.04.60 245   RE/33/G/01103 Sh. 2 - General formation of multiple tracks MG 06.04.62 246   RE/33/G/01104 Sh. 1 - Leading dimensions of turnouts BG 20.04.62 347   RE/33/G/01104 Sh. 2 - Leading dimensions of turnouts MG 17.05.62 2