DSEULTRA STARTING WITH QUALITY. ® ® SPECIFICATION DC SUPPLY  8V to 35V continuous CRANKING CRANKIN G DROPOU DROPOUTS TS  Able to survive 0V for 50mS, providing supply was at least 10V before dropout and supply recovers to 5V. This is achieved without the need for internal batteries. DSE710 & DSE SE7 720  AUTO  AU TO STAR ART T & AU AUTO TO MA MAIN INS S FAI AILU LURE RE CO CONT NTRO ROL L MO MODU DULE LES S MAXIMUM OPERATING CURREN MAXIMUM CURRENT T 180mA at 12V. 190mA at 24V MAXIMUM ST MAXIMUM STANDBY ANDBY CURRE CURRENT NT 145mA at 12V. 150mA at 24V GENERATOR INPUT RANGE 35V(L-N) to 333V AC (L-N) absolute maximum 50Hz - 60Hz (min 15V AC) DSE710  AUXILIARY OUTPUTS Solid state 2.4A DC at supply voltage DSE720 FUEL/START OUTPUTS Solid state 3.4A DC at supply voltage GENERATOR C.T. 5A secondary 0.5VA MAINS (UTI MAINS (UTILITY LITY)) SEN SENSINGINPUT SINGINPUT RANGE (DSE720 only) 35V(L-N) to 333V AC (L-N) 50Hz - 60Hz (min 15V AC) DSE710 & DSE DSE710 DSE720 720 DIM DIMENS ENSION IONS S 209mm x 146mm x 30.3mm 8.2” x 5.7” x 1.2” DSE710 & DSE DSE710 DSE720 720 PANE ANEL L CUTO CUTOUT UT:: 182mm x 137mm 7.2” x 5.4” The DS The DSE7 E710 10 is an Au Auto toma mati tic c Start Sta rt Con Contr trol ol Mod Module ule tha thatt off offers ers an ad adva vance nced d ra rang nge e of eng engine ine monitoring monit oring and pro protectio tection n featur fea tures es.. Th The e mo modu dule le has be been en design des igned ed to mo monito nitorr gene generat rator or frequency, freque ncy, generat generator or volts, generat gen erator or cur curren rent, t, engi engine ne oil pressure, press ure, engine coolan coolantt temperature tempe rature,, engine running hours hour s and bat batter tery y vol volts. ts. The mo The modu dule le al also so di disp spla lays ys th the e engine eng ine sp speed eed.. Wh When en th the e mo modu dule le dete de tect cts s a fau fault lt co cond ndit itio ion n it automat auto matica ically lly shut shuts s dow down n the engine eng ine and in indi dica cates tes th the e ex exact act fault fau lt on th the e mo modu dules les LC LCD D di disp splay lay or rel relevan evantt LED ind indicat icator or.. The mo The modu dule le can be co confi nfigu gure red d usin us ing g th the e fr fron ontt pa pane nell or vi via a th the e DSE8 DS E810 10 in inte terfa rface ce and a PC PC.. Th The e modu mo dule le ca can n al also so be co cont ntro rolle lled d fro fr om a PC th that at isloc islocat atedup edup to 100 met meters ers awa away. y. The DS The DSE7 E720 20 is an Au Auto toma mati tic c Mains Mai ns Fai Failur lure e Co Contr ntrol ol Mod Module ule and inc incorp orpora orates tes all the feat feature ures s of th the e DS DSE7 E710 10 pl plus us th the e ab abil ilit ity y to automat auto matica ically lly mo monito nitorr the mai mains ns suppl sup ply y and sw swit itch ch ov over er to th the e generat gen erator or whe when n the mai mains ns power pow er fai fails. ls. FEATURES • PC configurable • Digital and analogue inputs • Digital outputs • Automatic mains (utility) supply monitoring (DSE720 only) • Automatic shutdown or warning when fault conditions are detected • Manual start • Engine pre-heat • Engine monitoring and protection features • Protected Solid State (PSS) outputs • Front panel mounting • Front panel programming • Tamper proof engine hours counter • Remote start • LED indicators • Configurable timers • Configurable outputs • Configurable inputs • Back-lit character/icon LCD display BENEFITS • Transfer between mains (utility) and generator power (DSE720 only) • On-site module configuration and remote configuration (Max 100 Meters) using PC software • User-friendly set-up and button layout • Multiple engine parameters are monitored simultaneously • License free PC software OPERATION  The module is operated using the front STOP/RESET, MANUAL,  AUTO, TEST and START push buttons.  An additional push button next to the LCD display is used to scroll through the modules’ metering displays. CONFIGURATION  The modules can be configured using the front panel or remotely using the DSE810 interface and a PC.  As well as configuration the DSE810 interface has the ability to provide real time diagnostic facilities. MAXIMUM PA MAXIMUM PANEL NEL THICKNES THICKNESS S 8mm 0.3” ENVIRONMENTAL TESTING ENVIRONMENTAL STANDARDS ELECTRO MAGNE ELECTRO MAGNETIC TIC CAPABILIT ABILITY  Y  BS EN 61000-6-2 EMC Generic Emission Standard for the Industrial Environment BS EN 61000-6-4 EMC Generic Emission Standard for the Industrial Environment ELECTRICAL SAFETY  ELECTRICAL BS EN 60950 Safety of Information Technology Equipment, including Electrical Business Equipment TEMPERATURE BS EN 60068-2-2 o  Test Ab to +70 C 60067-2-2 Hot o  Test Ab to -30 C 60068-2-1 Cold  VIBRATION BS EN 60068-2-6  Ten  T en sweeps in each of three major axes 5Hz to 8Hz @ +/-7.5mm, 8Hz to 500Hz @ 2gn HUMIDITY  BS 2011 part 2.1 60068-2-30  Test  T est Cb Ob Cyclic o 93% RH @ 40 C for 48 hours SHOCK BS EN 60068-2-27  Three shocks in each of three major axes 15gn in 11mS DEEP SEA ELECTRONICS PLC Highfield House Hunmanby Industrial Estate Hunmanby, North Yorkshire  YO14 0PH England TELEPHONE +44 (0)1723 890099 EMAIL [email protected] FACSIMILE +44 (0)1723 893303 WEBSITE www.deepseaplc.com Registered in England & Wales No.01319649 VAT No.316923457 DEEP SEA ELECTRONICS INC 3230 Williams Avenue Rockford IL 61101-2668 USA TELEPHONE +1 (815) 316 8706 EMAIL [email protected] FACSIMILE +1 (815) 316 8708 WEBSITE www.deepseausa.com ® DSE710 & DSE720 MECHANICAL LOAD LOAD INSTRUMENTATION AND  ALARMS  The DSE710 and DSE720 both provide comprehensive metering and alarm facilities. DSE720 ONLY CTs MUST BE 5 AMP SECONDARY P1 P2 L1 S1 L1 S2 L2 FROM ENERATOR L2 L3  The table below outlines the module’s capabilities. L3 FROM MAINS N N DSE710/DSE720 2 AMP FUSES 2 AMP FUSES ELECTRICAL INTERLOCK Generator Frequency M G NORMALLY OPEN Engine Speed NORMALLYCLOSED Generator Volts (L1-N, L2-N, L3-N) Generator Volts (L1-L2, L2-L3, L3-L1) + + Generator Current (L1, L2, L3) Engine Oil Pressure Engine Coolant Temperature 18 L1 19 20 21 L2 L3 COM 26 L1 27 9 8 22 23 24 25 N      N      E      G      E      S      O      L      C      S      N      I      A L1 L2 L3 N GEN VOLTS MODULE 710/720 BATTERY      E      V    -      E      V     + 1 2 2 AMP FUSE BATTERY MAINS      K      N      A      R      C      1      T      U      P      T      U      O      2      T      U      P      T      U      O      T      L      A      G      R      H      C      E      R      U      S      S      E      R      P      L      I      O 7 10 11      P      O      T      S      M      E      L      E      U      F 3 4 5 6 FUEL SOLENOID CRANK SOLENOID RELAY Hours Run Counter Battery Volts      M      E      S      O      L      C      P      M      E      T      T      N      A      L      O      O      C 12 13      1      T      U      P      N      I      2      T      U      P      N      I      T      R      A      T      S      E      T      O      M      E      R 15 16 14 Mains Volts (DSE720 only) (L1-N, L2-N, L3-N) 17 2 AMP FUSE WL RELAY CHARGE  ALT      H      T      R      A      E      E      N      I      G      N      E      O      T BATTERY NEGATIVE MUST BE GROUNDED SCREW TERMINALS TIGHTENING TORQUE = 0.8Nm (7lb-in) * NOTE. ALL THE OUTPUTS ARE SOLID STATE AND ARE POSITIVE SWITCHING RELATED MATERIALS TITLE DSE710 Manual DSE720 Manual DSE7xx Software Manual PART NO’S 053-013 053-005 057-002 DEEP SEA ELECTRONICS PLC maintains a policy of continuous development and reserves the right to change the details shown on thisdata sheet withoutprior notice.The contents are intendedfor guidance only.  This data sheet is printed on 9lives 55 Silk, which is produced with 55% recycled fibre from both pre and post-consumer sources, together with 45% virgin ECF fibre. 055-035/02/08 (2)