Preview only show first 10 pages with watermark. For full document please download

Power Supplies

POWER SUPPLIES POWER SUPPLIES HUMIDITY Kele Stocks Most Major Brands and a Huge Inventory of Power Supplies You Need to Get the Job Done. XFMR Series | p. 977 E100E…

   EMBED

  • Rating

  • Date

    June 2018
  • Size

    1.7MB
  • Views

    3,291
  • Categories


Share

Transcript

POWER SUPPLIES POWER SUPPLIES HUMIDITY Kele Stocks Most Major Brands and a Huge Inventory of Power Supplies You Need to Get the Job Done. XFMR Series | p. 977 E100E | p. 981 RIB TR Series | p. 985 T-PB Series | p. 987 DCP-1.5-W | p. 995 DCP-250 Series | p. 996 POWER SUPPLIES POWER SUPPLIES Products manufactured in the United States Products that are new to the catalog PSH500A | p. 991 691 Series | p. 979 US Transformers | p. 983 kele.com MODEL/SERIESPAGE Power Supplies T-PB Series — Air Products and Controls Enclosed 24 VAC Power Source . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 987 PSB40AB10, PSB100AB10, PSC40AB10, PSC100AB10 — Functional Devices Enclosed 24 VAC Class 2 Power Source. . . . . . . . . . . . . . . . . . . . 988 PSH Series — Functional Devices Enclosed 24 VAC Class 2 Power Source . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 989 PSH200A, PSH300A, PSH500A, PSMN300A, and PSMN500A — Functional Devices Enclosed Power Source - 100 VA, 24 VAC Class 2 Outputs . . . . . 991 S1K and SDU Series — Sola/Hevi-Duty Uninterruptible Power Supplies - UPS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 992 PSH550-UPS — Functional Devices Uninterruptible Power Supply. . . . . . . . . 993 DCPA-1.2 — Kele AC / DC Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . 994 DCP-1.5-W — Kele DC Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 995 DCP-250 — Kele Enclosed DC Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . 996 DCP-524 — Kele DC Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 997 SLS Series — DC Power Supplies. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 998 PW2 — Compact DC Power Supply. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 999 AM-24830A — Plug-in Class 2 Transformer. . . . . . . . . . . . . . . . . . . . . . . . . . . 999 PS5R Series — IDEC Switching Power Supplies. . . . . . . . . . . . . . . . . . . . . . 1000 SDN-P Series — Din Rail Mount Power Supplies. . . . . . . . . . . . . . . . . . . . . . 1002 SDN-C Compact Series — Compact Din Rail Mount Power Supplies. . . . . . 1003 Transformers XFMR Series — Control Transformers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 691 Series — Kele Control Transformers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 691-U100 — Kele Class 2 Control Transformer. . . . . . . . . . . . . . . . . . . . . . . . . AT150F, AT175F — Class 2 Control Transformers with Breaker . . . . . . . . . . . E100E, E150E, E300E, E500E — Control Transformers . . . . . . . . . . . . . . . . . 694 Series — Multi-Tap Control Transformers with Breaker. . . . . . . . . . . . . . . US Transformers — US Made Transformers by Functional Devices. . . . . . . . 33 Series — 120 VAC Secondary Transformers. . . . . . . . . . . . . . . . . . . . . . . . RIB TR Series — Functional Devices Control Transformers. . . . . . . . . . . . . . . 977 979 979 980 981 982 983 984 985 NEW! NEW! POWER SUPPLIES CONTROL TRANSFORMERS XFMR SERIES DESCRIPTION The XFMR Series of voltage transformers provide nominal 24 VAC control voltage. These transformers are intended for NEMA 1 installation and should be installed in compliance with all national and local electrical codes. FEATURES ã ã ã ã VA ratings from 40 VA to 500 VA Low cost One year warranty UL Listed (File #E223965) (#E223966 for HD models) XFMR75HB XFMR50JA WIRING Primary Wires* 480 VAC Gray 120 VAC White 277 VAC Brown Common Black 240 VAC Orange 208 VAC Red XFMR100HC XFMR150FA Secondary Wires** 24 VAC Brown or Blue XFMRHD300E SPECIFICATIONS Model VA Rating Primary Voltage Secondary Voltage Frequency Circuit Breaker Mounting XFMR50HA 50 VA 120/208/240 VAC 24 VAC 50/60 No 1 Hub + Foot XFMR50JA 75 VA 120/208/240 VAC 24 VAC 50/60 No 1 Hub + Foot XFMR40FB 40 VA 120 VAC 24 VAC 50/60 No 2 Hub + Foot XFMR40FC 40 VA 24 VAC 24 VAC 50/60 No 1 Hub + Foot XFMR50FA 50 VA 120 VAC 24 VAC 50/60 No 2 Hub + Foot XFMR150FA 150 VA 120 VAC 24 VAC 50/60 Yes, 10A trip point 1 Hub + Foot XFMR175FA 175 VA 208/240 VAC 24 VAC 50/60 No 2 Hub + Foot XFMR240FA 240 VA 120 VAC 24 VAC 50/60 No 1 Hub + Foot XFMR375FA 375 VA 120 VAC 24 VAC 50/60 No 1 Hub + Foot XFMR40HA 40 VA 120/208/240 VAC 24 VAC 50/60 No 1 Hub + Foot XFMR50HB 50 VA 120/208/240/277/480 VAC 24 VAC 50/60 Yes, 2.5A trip point 1 Hub + Foot XFMR75HB 75 VA 120/208/240/277/480 VAC 24 VAC 50/60 Yes, 4A trip point 1 Hub + Foot XFMR75HC 75 VA 120/208/240/277/480 VAC 24 VAC 50/60 Yes, 4A trip point 2 Hub + Foot XFMR100HC 100 VA 120/208/240/480 VAC 24 VAC 50/60 Yes, 4A trip point 2 Hub + Foot XFMRHD100E 100 VA 120/240 VAC 24 VAC 50/60 No Foot XFMRHD150E 150 VA 120/240 VAC 24 VAC 50/60 No Foot XFMRHD300E 300 VA 120/240 VAC 24 VAC 50/60 No Foot XFMRHD500E 500 VA 120/240 VAC 24 VAC 50/60 No Foot March 2014 WE MAKE IT EASY. kele.com 888-397-5353 USA POWER SUPPLIES *XFMR40FC isolation tranformer features red 24 VAC primary wires **XFMR40HA, XFMR50HA feature secondary terminals 17 977 NEW! NEW! POWER SUPPLIES CONTROL TRANSFORMERS XFMR SERIES DIMENSIONS in (cm) Circuit Breaker B A D C E Mounting Hole STYLE 1 STYLE 2 Circuit Breaker WIRES WEIGHT lb (kg) STYLE 2.01 (5.1) 8.0 (20.3) 2.56 (1.16) 6 2 (5.08) 2.3 (5.84) 8.0 (20.3) 1.73 (0.79) 1 2.88 (7.3) 1.81 (4.6) 1.75 (4.4) 8.0 (20.3) 1.73 (0.79) 7 2.17 (5.5) 2.88 (7.3) 1.81 (4.6) 1.75 (4.4) 8.0 (20.3) 1.56 (0.71) 1 2.48 (6.3) 2.17 (5.5) 2.88 (7.30) 1.81 (4.6) 1.75 (4.4) 8.0 (20.3) 4.32 (1.95) 9 2.79 (7.09) 2.17 (5.5) 2.88 (7.3) 1.81 (4.6) 2.01 (5.1) 8.0 (20.3) 3.86 (1.75) 4 XFMR150FA 3.55 (9.01) 3.79 (9.6) 3.2 (8.1) 3.14 (7.76) 2.48 (6.30) 8.0 (20.3) 5.16 (2.45) 3 XFMR175FA 4.12 (10.46) 3.8 (9.7) 3.2 (8.13) 3.14 (7.98) 3.19 (8.10) 8.0 (20.3) 7.28 (3.09) 4 XFMR240FA 3.72 (9.4) 3.8 (9.7) 4.52 (11.4) 3.18 (8.1) 3.242 (8.2) 8.0 (20.3) 8.60 (3.91) 1 XFMR375FA 4.315 (11.0) 3.8 (9.7) 4.52 (11.4) 3.18 (8.1) 3.83 (9.7) 8.0 (20.3) 12.57 (5.71) 1 XFMR50HB 3.45 (9.3) 2.5 (6.4) 3.06 (7.8) 2.03 (5.2) 1.91 (4.9) 8.0 (20.3) 3.31 (1.50) 2 XFMR75HB 2.79 (7.09) 2.17 (5.50) 2.88 (7.30) 1.81 (4.60) 2.01 (5.1) 8.0 (20.3) 3.86 (1.75) 2 XFMR75HC 3.87 (9.8) 2.5 (6.4) 3.06 (7.80) 2.03 (5.2) 2.31 (5.9) 8.0 (20.3) 3.86 (1.75) 5 XFMR100HC 4.05 (10.29) 2.5 (6.4) 3.06 (7.80) 2.03 (5.2) 2.51 (6.38) 8.0 (20.3) 4.85 (2.20) 5 XFMRHD100E 3.35 (8.50) 2.89 (7.33) 3.38 (8.58) 2.93 (74.5) 2.81 (7.15) Terminals 4.20 (1.91) 8 XFMRHD150E 3.60 (9.15) 3.78 (9.60) 3.22 (8.18) 3.43 (8.72) 3.12 (7.93) Terminals 6 (2.73) 8 XFMRHD300E 4.80 (12.20) 4.49 (11.40) 3.88 (9.68) 3.13 (7.95) 3.74 (9.51) Terminals 9 (4.10) 8 XFMRHD500E 5.93 (13.70) 4.49 (11.40) 3.88 (9.68) 4.13 (10.50) 3.74 (9.51) Terminals 12.5 (5.68) 8 POWER SUPPLIES MODEL DIMENSIONS in (cm) C A B D E XFMR50HA 2.79 (7.09) 2.17 (5.5) 2.88 (7.3) 1.81 (4.6) XFMR50JA 3.88 (9.85) 2.5 (6.35) 3.04 (7.62) XFMR40FB 2.48 (6.3) 2.17 (5.5) XFMR40FC 2.48 (6.3) XFMR40HA XFMR50FA STYLE 3 STYLE 4 Circuit Breaker Secondary Screw Terminals STYLE 5 STYLE 6 Circuit Breaker STYLE 8 STYLE 7 Secondary Screw Terminals Double-Gang Plate STYLE 9 17 978 ORDERING INFORMATION MODEL XFMR50HA XFMR50JA XFMR40FB XFMR40FC XFMR50FA XFMR150FA XFMR175FA XFMR240FA XFMR375FA XFMR40HA XFMR50HB XFMR75HB XFMR75HC XFMR100HC XFMRHD100E XFMRHD150E XFMRHD300E XFMRHD500E 888-397-5353 USA DESCRIPTION Transformer 120/208/240:24 V 50 VA Transformer 120/208/240:24 V 75 VA Transformer 120:24 VAC 40 VA Transformer 24:24 VAC 40 VA Transformer 120:24 VAC 50 VA Transformer 120:24 VAC 150 VA Transformer 208/240:24 VAC 175 VA Transformer 120:24 VAC 240 VA Transformer 120:24 VAC 375 VA Transformer 120/208/240:24V 40VA Transformer 120/208/240/277/480:24 VAC 50 VA Transformer 120/208/240/277/480:24 VAC 75 VA Transformer 120/208/240/277/480:24 VAC 75 VA Transformer 120/208/240/480:24 VAC 100 VA Transformer 120/240:24 V 100 VA Transformer 120/240:24 V 150 VA Transformer 120/240:24 V 300 VA Transformer 120/240:24 V 500 VA kele.com WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE. March 2014 NEW! NEW! POWER SUPPLIES KELE CONTROL TRANSFORMERS 691 SERIES DESCRIPTION The 691 Series of stepdown voltage transformers provide nominal 24 VAC control voltage from 120 VAC primary supply. These transformers are designed for NEMA 1 locations. They should be installed in compliance with all national and local electrical codes. 691-K2A FEATURES ã ã ã ã ã Low cost Fully enclosed with metal end bells Compact size Resettable secondary circuit breaker (691-U100 Only) Dual threaded hubs (691-U100 Only) 691-U100 691-K1A 691-K0A SPECIFICATIONS Conduit Connection Operating Temperature 691-K0A 120 VAC 24 VAC 60 Hz 40 VA Hub or foot 691-K1A 120 VAC 24 VAC 50/60 Hz 100 VA Hub or foot 691-K2A 120 VAC 24 VAC 50/60 Hz 170 VA Hub or foot 691-U100 120 VAC 24 VAC 60 Hz 96 VA Hub or foot 1/2 (1.3 cm) male threads 1/2 (1.3 cm) male threads 1/2 (1.3 cm) male threads Two 1/2 (1.27 cm) male connections 14° to 104°F (-10° to 40°C) 14° to 104°F (-10° to 40°C) 14° to 104°F (-10° to 40°C) Wire Length Weight Warranty Approvals 32° to 104°F (0° to 40°C) 8 (20.3 cm) 2.1 lb (0.95 kg) 1 year 8 (20.3 cm) 3.5 lb (1.6 kg) 1 year 8 (20.3 cm) 6.3 lb (2.9 kg) 1 year 8 (20.3 cm) 4.9 lb (2.2 kg) 3 years UL1585, UL5085-1 & 3 listed, Class 2 File #E99227 UL1585, UL5085-1 & 2 listed, (not class 2) File #E250952 UL1585, UL5085-1 & 2 listed, (not class 2) File #E250952 UL1585 listed, Class 2, File #E316704 - - - Manual reset, 4A trip Circuit Breaker POWER SUPPLIES Model Primary Voltage Secondary Voltage Frequency VA Rating Mounting DIMENSIONS / WIRING C E in (cm) Primary (120 VAC) Black (120V), White (N) D B 1/2 (1.3 cm) Male Conduit Threads 691-K2A A 2.6 (6.7) 3.1 (8.0) 3.13 (7.95) 3.2 (8.13) 1/2 (1.3 cm) Male Conduit Threads Secondary Wires (24 VAC) Brown (COM), Red (24 V) B C D 3.0 3.2 2.5 (7.7) (8.2) (6.4) 3.8 4.1 3.3 (9.6) (10.3) (8.3) E 2.2 (5.7) 2.4 (6.1) 691-K1A/691-K2A Transformers 4.0 (10.16) 8 (20.32) Primary Wires (120 VAC) Black (120V) / White (N) Primary Wires (120 VAC) Black (120 V), White (N) DIMENSIONS MODEL 3.0 (7.62) A Secondary (24 VAC) Red, Red 691-K1A 3.12 (7.93) 3.80 (9.65) 3.13 (7.95) 17 3/8 x 3/16 Slots (4) (0.953) x (0.476) Circuit Breaker 2.5 (6.35) 2.06 (5.23) 691-K0A Transformer 691-U100 8 (20.32) Secondary Wires (24 VAC) Brown (COM) / Orange (24V) ORDERING INFORMATION MODEL 691-K0A 691-K1A 691-K2A 691-U100 March 2014 DESCRIPTION Control transformer, 120:24 VAC, 40 VA, Class 2 Control transformer, 120:24 VAC, 100 VA Control transformer, 120:24 VAC, 170 VA Class 2 control transformer, 120:24 VAC, 96 VA WE MAKE IT EASY. kele.com 888-397-5353 USA 979 NEW! NEW! POWER SUPPLIES CLASS 2 CONTROL TRANSFORMERS WITH BREAKER AT150F, AT175F DESCRIPTION Model AT150F and AT175F transformers provide power to nominal 24 VAC circuits in heating/cooling systems. Although the transformers are typically used in heating/cooling systems, they can be used in any application that does not exceed the load ratings. The transformers include a manual reset button for resetting the circuit breaker. They also meet NEC Class 2 not wet and Class 3 wet requirements and are UL listed under UL1585. These transformers can be foot or hub mounted. FEATURES ã ã ã ã Multi-tap primary connections Color-coded lead wires Manually resettable circuit breaker Meets NEC Class 2 not wet and Class 3 wet transformer requirements DIMENSIONS SPECIFICATIONS POWER SUPPLIES Primary Voltage Secondary Voltage Frequency VA Rating Mounting Conduit Connection Lead Wires Weight Approvals Warranty 17 in (cm) 120/208/240 VAC, 208/277/480 VAC 24 VAC 60 Hz AT150F: 50 VA, AT175F:75 VA Foot or hub 1/2 male NPT 9 (22.8 cm), color coded 3 lb (1.36 kg) UL1585, UL5085-3 listed, File #E14881, CSA approved, File #LR95329-18 NEC Class 2 not wet , Class 3 wet 1 year 0.44 (1.18) A DIMENSIONS B 0.44 (1.18) 1/2 NPT MODEL AT150F AT175F A B C 1.75 (4.5) 1.75 (4.5) 3.63 (9.3) 2.13 (5.4) 1.75 (4.5) 3.94 (10.2) Reset Button 3.19 (8.10) 0.69 (1.78) 2.19 (5.56) C WIRING Common** 120V Primary* Wires 208V 240V (black) 24 VAC Secondary Wires (white) (red) (orange) Common** (yellow) (blue) 208V (black) Primary* Wires 277V 480V 24 VAC Secondary Wires (red) (brown) (black/red) 120/208/240 VAC Models (yellow) (blue) 208/277/480 VAC Models * Insulate the ends of the unused primary leads by taping or capping with a solderless connector. ** Black is common with respect to the transformer windings only, not the external circuit. ORDERING INFORMATION MODEL AT150F1022 AT150F1030 AT175F1023 AT175F1031 980 888-397-5353 USA DESCRIPTION Control transformer, 120/208/240:24 VAC, 50 VA with breaker Control transformer, 208/277/480:24 VAC, 50 VA with breaker Control transformer, 120/208/240:24 VAC, 75 VA with breaker Control transformer, 208/277/480:24 VAC, 75 VA with breaker kele.com WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE. March 2014 NEW! POWER SUPPLIES CONTROL TRANSFORMERS E100E, E150E, E300E, E500E DESCRIPTION Models E100E, E150E, E300E, and E500E are premium performance, epoxy-encapsulated control transformers used in temperature control systems and industrial applications. These transformers are able to meet high inrush loads while providing outstanding voltage regulation, more efficient (cooler) operation, and simple installation and wiring. They are designed to provide 24 VAC control voltage from a 120/240 VAC primary supply. FEATURES ã Precise spacing between interleaved windings for maximized voltage regulation ã Oversized copper windings contribute to low temperature rise ã Solid epoxy-encapsulation to dissipate heat efficiently and completely seal coil against moisture, dirt, and other airborne contaminants ã Ten year warranty DIMENSIONS SPECIFICATIONS in (cm) 120/240 VAC, 50/60 Hz 24 VAC 100 VA, 150 VA, 300 VA, 500 VA 221°F (105°C) Plated brass binder head screws 131°F (55°C) Slotted feet H1 H3 H2 H4 D H X2 4.2 lb (1.9 kg) 7.0 lb (3.2 kg) 11.8 lb (5.4 kg) 17.6 lb (7.99 kg) UL506, UL5085-1 & 2 listed, File #E77014 CSA certified, File #LR14328-22 10 years X1 W MODEL DIMENSION E100E E150E D 4 .64 (11 .8) 4 .48 (11 .4) W 3 .38 (8 .6) 4 .50 (11 .4) H 2 .87 (7 .31) 3 .82 (9 .7) E300E 5 .09 (12 .9) 5 .25 (13 .3) 4 .45 (11 .3) E500E 6 .32 (16 .1) 5 .25 (13 .3) 4 .45 (11 .3) POWER SUPPLIES Primary Voltage Secondary Voltage VA Rating Insulation Class Terminals Temperature Rise Mounting Weight E100E E150E E300E E500E Approvals Warranty WIRING 120 VAC * H1 240 VAC * H3 24 VAC * H2 H4 H1 H3 *Jumper clips provided. Primary Wiring H2 H4 X2 X1 Secondary Wiring Recommended Fuses (max amps) E100E: FLM-5 E150E: FLM-10 E300E: FLM-20 E500E: FLM-30 Secondary fuse holders (FB2X) are included with all tranformers. Use a 13/32 x 1-1/2 cartridge fuse. 17 ORDERING INFORMATION MODEL E100E E150E E300E E500E IP20 SBEDIN March 2014 DESCRIPTION Control transformer, 120/240:24V, 100 VA Control transformer, 120/240:24V, 150 VA Control transformer, 120/240:24V, 300 VA Control transformer, 120/240:24V, 500 VA ACCESSORIES Terminal cover kit for E Series Transformers DIN circuit breaker mounting kit WE MAKE IT EASY. kele.com 888-397-5353 USA 981 POWER SUPPLIES NEW! MULTI-TAP CONTROL TRANSFORMERS WITH BREAKER 694 SERIES DESCRIPTION The 694 Series of industrial-grade multi-tap stepdown voltage transformers with manual resettable current-limiting secondary circuit breakers is ideal for use in temperature control systems. These UL listed transformers provide 24 VAC control voltage from a 120-480 VAC primary supply. The leads are clearly marked for ease of wiring. These foot-mounted transformers are designed for NEMA 1 locations and should be installed in compliance with all national and local electrical codes. FEATURES ã Multi-tap primary from 120-480 VAC ã Manual resettable secondary circuit breaker ã Foot mounting SPECIFICATIONS Primary Voltage Secondary Voltage Frequency VA Rating 120, 208, 240, 480 VAC 24 VAC 60 Hz 694-M1A: 75 VA, 694-M2A: 100 VA, 694-M3A: 180 VA, 694-M4: 300 VA 694-M1A: Manual reset, 5A trip, 694-M2A: Manual reset, 6A trip, 694-M3A: Manual reset, 12A trip, 694-M4: Manual reset, 16A trip 356°F (180°C) 10 (25.4 cm) 144°F (80°C) Foot UL506 listed, File #E67824, UL506 listed, File #E3210 POWER SUPPLIES Circuit Breaker Insulation Class Wire Length Temperature Rise Mounting Approvals Weight 694-M1A, 694-M2A 694-M3A 694-M4 Warranty 17 DIMENSIONS in (cm) C E B D Circuit Breaker 3.8 lb (1.7 kg) 6.5 lb (3.0 kg) 15.0 lb (6.8 kg) 1 year A WIRING M1A/M2A/M3A M4 Black Black Common White White 120 VAC Orange Red 208 VAC Brown Orange 240 VAC Gray Gray 480 VAC 0 Circuit Breaker 24 120 24 VAC (Blue) 0 Neutral (Brown) 208 240 480 Secondary Wiring Primary Wiring* MODEL 694-M1A A 2.50 (6.35) 694-M2A 2.50 (6.35) 694-M3A 3.78 (9.60) 694-M4 4.52 (11.48) DIMENSIONS B C D E 3.00 4.52 2.50 2.25 (7.62) (11.48) (6.35) (5.72) 3.00 4.52 2.50 2.25 (7.62) (11.48) (6.35) (5.72) 3.15 5.05 2.45 3.51 (8.00) (12.83) (6.22) (8.92) 3.75 5.42 3.16 3.8 (9.53) (13.77) (8.03) (9.65) * Insulate the ends of unused primary leads. ORDERING INFORMATION MODEL 694-M1A 694-M2A 694-M3A 694-M4 982 888-397-5353 USA DESCRIPTION Control Transformer, 120/208/240/480:24 VAC, 75 VA Control Transformer, 120/208/240/480:24 VAC, 100 VA Control Transformer, 120/208/240/480:24 VAC, 180 VA Control Transformer, 120/208/240/480:24 VAC, 300 VA kele.com WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE. March 2014 NEW! POWER SUPPLIES US MADE TRANSFORMERS BY FUNCTIONAL DEVICES US TRANSFORMERS DESCRIPTION These US Made Transformers come in 40VA, 50VA and 100VA options. They are Class 2 and have UL, CE and cUL approvals. They all feature split bobbin construction. Some also have a secondary circuit breaker. FEATURES ã ã ã ã Foot and Hub mounted models available Class 2 rated Color coded wire leads Meets Buy American ARRA 2009 TR100VA100US WIRING Primary Wires 480 VAC Gray 277 VAC Brown 240 VAC Orange 208 VAC Red 120 VAC Common Secondary Wires 24 VAC Yellow 24 VAC Yellow/White White Black SPECIFICATIONS Supply Voltage Supply Frequency Secondary Voltage Over Current Protection Mounting Weight TR40VA001US 120VAC 50/60Hz 24VAC Inherently Limited Foot & Single Threaded Hub 2.02 lbs. TR40VA002US 120VAC 50/60Hz 24VAC Inherently Limited Foot & Dual Threaded Hubs 2.05 lbs. TR50VA001US 120VAC 50/60Hz 24VAC 3 Amp Fuse Foot & Single Threaded Hub 2.14 lbs. TR50VA004US 120/240/277/480VAC 50/60Hz 24VAC Circuit Breaker Foot & Dual Threaded Hubs 3.04 lbs. TR50VA005US 120VAC 50/60Hz 24VAC Circuit Breaker Foot & Single Threaded Hub 2.60 lbs. TR100VA001US 120VAC 50/60Hz 24VAC Circuit Breaker Foot & Single Threaded Hub 4.06 lbs. TR100VA002US 120VAC 50/60Hz 24VAC Circuit Breaker Foot & Dual Threaded Hubs 4.13 lbs. TR100VA004US 120/240/277/480VAC 50/60Hz 24VAC Circuit Breaker Foot & Dual Threaded Hubs 4.60 lbs. POWER SUPPLIES Model DIMENSIONS in (cm) Circuit Breaker B A D C E MODEL Mounting Hole A B DIMENSIONS in (cm) C STYLE 1 D E STYLE 2 Circuit Breaker STYLE TR40VA001US 2.7 (6.9) 2.2 (5.6) 2.875 (7.3) 1.75 (4.4) 1.93 (4.9) TR40VA002US 2.7 (6.9) 2.2 (5.6) 2.875 (7.3) 1.75 (4.4) 1.93 (4.9) 2 TR50VA001US 2.75 (7) 2.2 (5.6) 2.875 (7.3) 1.75 (4.4) 1.93 (4.9) 1 TR50VA004US 3.5 (8.9) 2.525 (6.4) 3.25 (8.3) 2 (5.1) 1.95 (5) 4 TR50VA005US 3.5 (8.9) 2.525 (6.4) 3.25 (8.3) 2 (5.1) 1.95 (5) 5 TR100VA001US 3.5 (8.9) 2.5 (6.4) 3.25 (8.3) 2 (5.1) 2.55 (6.5) 1 TR100VA002US 3.5 (8.9) 2.5 (6.4) 3.25 (8.3) 2 (5.1) 2.55 (6.5) 2 TR100VA004US 3.5 (8.9) 2.5 (6.4) 3.25 (8.3) 2 (5.1) 2.75 (7) 4 17 1 STYLE 5 STYLE 4 ORDERING INFORMATION MODEL TR40VA001US TR40VA002US TR50VA001US TR50VA004US TR50VA005US TR100VA001US TR100VA002US TR100VA004US March 2014 DESCRIPTION US made 40VA, 120-24V inhere