Preview only show first 10 pages with watermark. For full document please download

Quickstart “basic” Guidelines For Standard

   EMBED


Share

Transcript

QUICKSTART “BASIC” GUIDELINES FOR STANDARD MODEL 6050/6100 - FOR GATES UP TO 10 FEET AND OPENING 90° Models 6050/6100 is intended for installation only on swing gates used for vehicles. Pedestrians must be supplied with a separate access opening. 120 Glasgow Avenue Inglewood, California 90301 For safety and installation instructions, please refer to the Installation/Owner’s manual. U.S.A. Gate Bracket Open Gate e at Br t ke ac e as Chassis Ground e at G t ke ac Br Sh A ow ad .5” Lo Important: The elbow assembly must be in the correct position on the arms BEFORE cycling operator the first time. op 4” 24 ” 23” Elbow Flange Output Shaft 20 B 12” Post Base Output Shaft 10” 10” 18.5” 14” Right Support Leg Concrete Run conduit on the opposite side of the open gate for the post base. Open Gate Open Gate Post Base MUST be Level. Conduit 2.5” 12” 3” t Bo Pad Base 3” Left Support Leg 2” Conduit 6” Output Shaft Position 22” Concrete Pad tom f te o Pla 24” 3/8 Secure operator to the concrete pad with four (4) 3/8” x 3” sleeve anchors (not supplied). le igh xib it HVolt e l F du on C Pad MUST be Level. ith ”w 3/4 eeps Sw ACwer Ponduit Co uit p Loo w Lo lt Vo 0 630 nd Co nk Po 1 we rA rm Crank Power Arm will remain stationary during manual gate movement. Manual Release Arms and Operator MUST be level. Gate Bracket 30” Crank Arm 5” Flange 60” Connecting Arm Varies with base used. Ground Copyright 2013 DoorKing, Inc. All rights reserved. Brass Bushing Elbow Assembly B SW 1 2 Arm Assembly and Gate Bracket Height the of is h pt e De ncret by o c ined s rm ition e t de cond ocal l l soi and des. o gc ldin i u b ctio Jun xes o nB m Post Base 24” 43” D Cra Ar 26” 43” A k Note: 2” thick gate Illustrated. 7 an Mount the post base into the concrete before installing the operator. 90° • NO AC power. • NO DC power (On select models). 0 #2 to #11 m Co to 7 1. elay t to # R l . 2 4 Vo 2 3. C Closed Gate 90° 11 Using shadow loop and gate opening in direction shown. Auto Close 1. OFF Timer 2. OFF Cr Concrete Position Closed Gate High Voltage Conduit DIP-Switch Settings Safety Cover Elbow Assembly Important: Elbow flange MUST be on the opposite side of the closed gate. Manually adjust the arms to get the correct open and closed positions BEFORE powering up the operator. Open/Close limits will be automatically set the first time operator is cycled. 115 VAC HIGH VOLTAGE! G B st Po 43” 37 Important: A straight line drawn from the closed gate bracket through the open gate bracket MUST intersect the operator output shaft. DANGER se Ba Note: 2” thick gate Illustrated. D d Pa 90° Tip: It is recommended that a surge suppressor be installed on the high voltage power lines. 115 VAC Closed Gate GATE OPERATOR MUST BE PROPERLY GROUNDED!! Neutral 12” op Lo 34” High Voltage Connection se er ev R Operator Position Crank Power Arm Important: Adjust the locknut on the crank power arm so that it is snug against the washer, but will still allow the 30” crank arm to rotate with little force. SW 2 3. OFF 4. ON 5. ON (Operator Type) 6. OFF 7. ON (Single Operator) 8. ON (Tamper Protect) Adjust 1 to 23 sec. 1. OFF (Opening Counter-Clockwise) 2. OFF (See reverse side) 3. OFF 4. OFF 5. OFF (Normal Reverse Function) 6. OFF 7. OFF 8. OFF Loop Detectors C Not included - Refer to the Installation/Owner’s manual and Loop Information Manual (available FREE from www.dkaccess.com) for more information on loops and loop detectors. Radio Receiver D Not included - Refer to a specific Radio Receiver Manual (available from www.dkaccess.com) for more information on radio receivers and antenna installation. (See reverse side for wiring) 6050-066-E-1-13 QUICKSTART “BASIC” GUIDELINES FOR MODEL 6050/6100 - DIP-SWITCH AND WIRING REFERENCE SW 1 DIP-Switches 4 5 SW 1 6 1-OFF 1-OFF 1-ON 1-ON Exit Loop Port Output Full Open Input Auto-Close Timer Slide Gate Swing Gate 3-Button Single Button 7 Dual Operators Single Operator 8 Tamper Protect 2-OFF 2-ON 2-OFF 2-ON Function U.S.A. Relay activates when gate is open (Shadow loop setting when used). Relay activates when gate is not closed. Relay activates when gate is opening and open. Relay activates when gate is opening and closing. The output wired to terminal #12 becomes the output from the exit loop detector plugged into the EXIT Loop port. ON Normal Setting. Terminal #12 is a normal full open input. (2) Two 115 VAC Convenience Outlets On 6100 with Convenience Open Model ONLY. Auto-close timer is OFF. Manual input required to close gate. Auto-close timer is ON. Adjustable from 1-23 seconds to close gate. OFF for Slide gate operator (DO NOT use for 6050/6100). Normal Setting. ON for Swing gate operator (Switch MUST be ON for 6050/6100). OFF OFF when using a 3-button station (DoorKing 3-button control stations only). ON ON when using a single button control. OFF Switch must be OFF when bi-parting (dual) gates are used. ON Switch must be ON for single operator. OFF ON OFF ON Antenna mounted outside operator cover. Important: Controls must be installed Coax Antenna Kit P/N 1514-073 a minimum of 10-feet from the gate or installed in such a way that the person using the control cannot come in contact with the gate or gate operator. #11 - Access Control Devices 1 Note: After a DIP-switch setting is changed, power must be turned OFF and then turned back on for the new setting to take affect. Setting Description Opens Clockwise Opens Counter-Clockwise ON 3 Self-Test Motor Control for Secondary Operator 7 Not Used 8 Not Used OFF ON Primary and secondary operators start at the same time. Secondary operator starts 1-2 seconds prior to primary operator. OFF OFF Leave in the OFF position. Leave in the OFF position. Magnetic Lock Note: All stand-alone and telephone entry devices must use a separate power source. Power (24 Volt DC) and logic output. Power is shut off .5 sec. prior to gate starting and remains off while gate is opening and in the open position. #12 - Safety Opening Device SW 1 SW 1, switch 3 must be ON. Com Com 24 Volt 1 amp max. 13 14 15 16 17 18 19 Com 20 Com SW 1 NC NO 1 2 3 4 5 6 7 8 Gate Overlap Radio Open ON 6 6 7 8 9 10 Access 11 Device Open 12 Safety Open Stand-Alone Card Reader ON Reverse Loop Shadow Loop OFF Normal Setting. Normal operation. ON Self-test mode. Operator MUST be disconnected from gate to run self test. Switch is OFF when both primary and secondary operator motors are powered OFF from main terminals 4 and 5. Applies to operators originally manufactured with 4501, Rev O boards or lower). Switch is ON when secondary operator motor is powered from the secondary ON motor terminals. Applies to operators manufactured with 4501, Rev P boards and higher, and all 4502 boards. Terminal 15 is a normal Reverse input. OFF ON Terminal 15 is a Shadow input. Gate will NOT stop during the close cycle. Stand-Alone Keypad 1 2 3 4 5 6 7 8 5 White Com 1 2 3 4 5 6 7 8 4 Green Close Key Switch OFF Same as above, for secondary operator ONLY. Red Open 2 3 4 5 ON 1 2 3 4 5 6 7 8 SW 2 2 Convenience Open Radio Receiver Note: Wiring may differ. See section 7 in the Installation/Owner’s manual for more info. 1 Telephone Entry DoorKing ONLY ON Secondary Operator Opening Direction 3-Wire Radio Receiver Limited to 250 ma. OFF Tamper protect is OFF. ON Normal Setting. Tamper protect is ON. 3-Button Station Primary Operator Opening Direction 120 Glasgow Avenue Inglewood, California 90301 For safety and installation instructions, please refer to the Installation/Owner’s manual. OFF SW 2 DIP-Switches Switch Description 24 Volt ON 1 2 3 4 5 6 7 8 3 Circuit Board Relay Setting Relay 1 and 2 Function Model 6050/6100 is intended for installation only on swing gates used for vehicles. Pedestrians must be supplied with a separate access opening. Com Switch Every time the operator is powered up, the First open command will automatically set the open and close limits of the gate. SW 2 SW 1 SW 2